Invert logical
output
negates the electrical output signal
Function selects between the functions described in 14.4.1 Selecting Functions
First antenna the first antenna for the selected function
Last antenna
the last antenna for the selected function
Turn-off time
sets the time for how long the output is on for the Tag found and Tag operation
successful function
Get
reads the current IO configuration settings
Set
sets the output settings
1) All SRU-8X1X readers have GPIO
14.6.2 Test Input and Output
Fig. 42: GPIO: Test Input and Test Output
Test Input
Each input channel has two configuration parameters available:
Input 14
shows logical input 1–4; will only be shown if Invert logical input for the respective
input has been checked at IO Configuration ( in Figure 41)
Read inputs reads the inputs once
Read inputs
cyclic start/stop
reads the inputs in a loop/stops the reading
Test Output
Output selects output 1–4 by means of the drop-down menu
Ź In order to use this function, select the Protocol access function for the
respective output, see 14.6.1 IO Configuration and 14.4.1 Selecting Functions.
Duration
sets time in ms after which the output automatically returns to its idle mode either
by moving the bar or by entering the value
If the duration is set to its maximum value (65535), the output is permanently on.
Set output on switches on the output
Set output off switches off the output