HD 1.8/13 C Ed R e w gis w w. te ka r a er n ch d er .
IMPORTANT SAFETY INSTRUCTIONS 몇 WARNING When using this product basic precautions should always be followed, including the following: 1 Read all the instructions before using the product. 2 High pressure jets can be dangerous if misused. The jet must not be directed at persons, animals, electrical devices, or the unit itself. 3 To reduce the risk of injury, close supervision is necessary when a product is used near children. 4 Know how to stop the product and bleed pressures quickly.
GROUND FAULT CIRCUIT INTERRUPTER PROTECTION This Product is supplied with a Ground Fault Circuit Interrupter (GFCI) built into the power cord plug. This device provides additional protection from the risk of electric shock. If power is interrupted in the line, the GFCI will automatically re-close the circuit to the load after power is restored. Depending on the GFCI model, it may be necessary to manually operate the reset button to restore power to the GFCI load circuit.
sion cords. Examine extension cord before using and replace if damaged. Do not abuse extension cord and do not yank on any cord to disconnect. Keep cord away from heat and sharp edges. Always disconnect the extension cord from the receptacle before disconnecting the product from the extension cord. If you are using an extension cord, it should always be completely unwound from the cable drum. Up to 100 ft = 12/3 AWG.
19 20 21 22 23 24 Push handle Cable clamp Clamping screw for pushing handle Detergent suction hose with filter Dosage valve for detergent Accessory compartment Safety instructions – – – Before first start-up it is definitely necessary to read the operating instructions and safety indications Nr. 5.951-949! Please follow the national rules and regulations for fuel spray jets of the respective country. Please follow the national rules and regulations for accident prevention of the respective country.
Environmental protection Attaching the Accessories Mount the nozzle on the spray pipe The packaging material can be recycled. Please do not throw the packaging material into household waste; please send it for recycling. Old appliances contain valuable materials that can be recycled; these should be sent for recycling. Batteries, oil, and similar substances must not enter the environment. Please dispose of your old appliances using appropriate collection systems.
plug. It is forbidden to permanently connect the appliance to the power supply. The plug is only for mains separation. Check the power cord with mains plug for damage before every use. If the power cord is damaged, please arrange immediately for the exchange by an authorized customer service or a skilled electrician. The plug and coupling of the extension cable used must be watertight. Use the extension cord that has an adequate cross-section (see "Technical Data") and unwind it fully from the cable drum.
Unlock the hand-spray gun and pull Operation the lever of the gun. Danger Risk of explosion! Do not spray flammable liquids. If the appliance is used in hazardous areas (e.g. filling stations) the corresponding safety provisions must be observed. Danger Long hours of using the appliance can cause circulation problems in the hands on account of vibrations.
Recommended cleaning method Frost protection Spray the detergent sparingly on the dry surface and allow it to react, but not to dry. Spray off loosened dirt with the high-pressure ray. After operations, dip the filter in clear water. Turn the dosing valve to the highest detergent concentration. Start the appliance and rinse for one minute. Interrupting operation Release the lever of the hand-spray gun; the device will switch off.
Maintenance and care Weekly Check oil level Please contact Cus- Danger Risk of injury by inadvertent startup of appliance and electrical shock. First pull out the plug from the mains before carrying out any tasks on the machine. Note Please dispose off used oil only in the collection points provided for them. Please hand over old oil, if any, only at such places. Polluting the environment with used oil is a punishable offence.
Appliance is not running Check connection cable for damag- es. Set nozzle to "CHEM". Check/ clean detergent suction Check the supply voltage. Call Customer Service in case of electrical defects. Pressure does not build up in the appliance Set nozzle to "High pressure". Clean the nozzle. Replace the nozzle. Deaerate the appliance (see "Startup") Check water supply level (refer to technical data). Clean the sieve in the water connection. Check all inlet pipes to the pump.
Technical specifications Main Supply Voltage Current type Connected load Protection (slow, char. C) Type of protection Extension cord 100 ft/30 m Water connection Max. feed temperature Min. feed volume Suck height from open container (20 °C) Max. feed pressure Performance data Working pressure Max. operating over-pressure Nozzle size Flow rate Detergent suck in Max.