Clipper Duo English 02 From Serial Number (Ref No1*) *See Serial Number Page in Spare Parts List or call manufacturer Register your product www.kaercher.
Machine Data Label Overview This carpet extractor is an electrical powered, portable carpet extractor intended for commercial use. The appliance sprays a cleaning solution onto the carpet, agitates the wet carpet, and then extracts the soiled solution back into the unit's recovery tank. The appliance is fitted with and a hand tool for cleaning upholstery and stairs. MODELS: 1.008-048.0 CLPDU Warranty Registration Thank you for purchasing a Kärcher North America product.
Table of Contents Machine Data Label . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 How To Use This Manual . . . . . . . . . . . . . . . . . . . . . 4 Safety IMPORTANT SAFETY INSTRUCTIONS . . . . . . . . . 5 CONSIGNES DE SÉCURITÉ IMPORTANTES . . . . 6 HAZARD INTENSITY LEVEL . . . . . . . . . . . . . . . . . . 7 NIVEAU D'INTENSITÉ DU DANGER . . . .
How To Use This Manual This manual contains the following sections: • • • • How to Use This Manual Safety Operations Maintenance The HOW TO USE THIS MANUAL section will tell you how to find important information for ordering correct repair parts. Parts may be ordered from authorized dealers. When placing an order for parts, the machine model and machine serial number are important. Refer to the MACHINE DATA box which is filled out during the installation of your machine.
Safety IMPORTANT SAFETY INSTRUCTIONS When using this machine, basic precaution must always be followed, including the following: READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE. To reduce the risk of fire, electric shock, or injury: Connect to a properly grounded outlet. See Grounding Instructions. Do not leave the machine unattended. Unplug machine from outlet when not in use and before maintenance or service. Use only indoors. Do not use outdoors or expose to rain.
Safety CONSIGNES DE SÉCURITÉ IMPORTANTES Lors de l'utilisation de cette machine, des précautions de base doivent toujours être prises, y compris les précautions suivantes : LIRE TOUTES LES INSTRUCTIONS AVANT D'UTILISER CETTE MACHINE. Pour réduire le risque d'incendie, d'électrocution ou de blessure : Cet appareil ne doit être connecter qu a des prises ayant une sortie de terre. Ne pas laisser l'appareil sans surveillance lorsqu'il est branché.
Safety The following symbols are used throughout this guide as indicated in their descriptions: HAZARD INTENSITY LEVEL There are three levels of hazard intensity identified by signal words -WARNING and CAUTION and FOR SAFETY. The level of hazard intensity is determined by the following definitions: WARNING - Hazards or unsafe practices which COULD result in severe personal injury or death. CAUTION - Hazards or unsafe practices which could result in minor personal injury or product or property damage.
Safety Les symboles suivants sont utilisés dans tout ce manuel, tels que décrits ici : NIVEAU D'INTENSITÉ DU DANGER Il existe trois niveaux d'intensité du danger, identifiés par des termes d'avertissement - AVERTISSEMENT, ATTENTION et POUR VOTRE SÉCURITÉ. Le niveau d'intensité du danger est déterminé par les définitions suivantes : AVERTISSEMENT - Les dangers ou des pratiques contraires à la sécurité qui POURRAIENT entraîner des blessures personnelles ou la mort.
Safety Safety Labels NOTE: These drawings indicate the location of safety labels on the machine. If at any time the labels become illegible, promptly replace them. Emplacement De L'étiquette De Sécurité Les ÉTIQUETTES D'AVERTISSEMENT suivantes se trouvent sur votre unité de nettoyage. Ces étiquettes signalent les avertissements et mises en garde importantes qui doivent être suivis en tout temps.
Safety Grounding Instructions . Electrical In the USA this machine operates on a standard 15 amp 115 volt A.C. power circuit. The amp, hertz, and voltage are listed on the data label found on each machine. Using voltages above or below those indicated on the data label will cause serious damage to the motors Extension Cords If an extension cord is used, the wire size must be at least one size larger than the power cord on the machine, and must be limited to 50 feet (15.5m) in length.
Safety Instructions De Mise À La Terre Cet appareil doit être relié à la terre. S'il fonctionne mal ou tombe en panne, la mise à la terre fournit un chemin de résistance moindre au courant électrique pour réduire le risque d'électrocution. Cet appareil est fourni avec un cordon équipé d'un conducteur de mise à la terre d'équipement et d'une fiche de terre.
Operations Technical Specifications ITEM Construction Vacuum Motor Solution Pump Brush Motor Brushes Cleaning Path Flow Rate Solution Spray Solution Tanks Recovery Tank Vacuum Shoe Wheels Power Cable Weight DIMENSION/CAPACITY Steel chassis with rotationally molded polyethylene tanks Three stage, bypass, 1.5 hp (1,119 watts), 100 cfm (2.8m³/min), 120" (3050 mm) waterlift 100 psi (7 bar) - Restorative 50 psi (3.
Operations ITEM Height Length Width Width of scrub path MEASURE 43 inches (1092 mm) 40.5 inches (1029 mm) 22 inches (559 mm) 16 inches (406 mm) HEIGHT LENGTH WIDTH This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Operations How this machine works This carpet extractor is an electrical powered, portable carpet extractor intended for commercial use. The appliance sprays a cleaning solution onto the carpet agitates the wet carpet, and then extracts the soiled solution back into the unit's recovery tank. The appliance is fitted with and a hand tool for cleaning upholstery and stairs. The machine is designed to maintain your carpet using the Encapsulating Interim Carpet Cleaning Process.
Operations 1 2 3 4 8 6 7 5 9 Components 1. Control Panel 2. Recovery Dome 3. Recovery Drain Hose 4. Recovery Tank 5. Scrub Deck 6. Solution Fill Cover 7. Solution Drain Hose 8. Solution Tank 9.
Operations 3 5 1 2 4 6 7 Controls 1. Hand Tool Switch 2. Main Switch 3. Light Cleaning 4. Deep Cleaning 16 5. Continuous Spray 6. Intermittent Spray 7.
Operations Filling The Solution Tank Do not put defoamer, solvents, spotter or prespray chemicals in the solution tank. Do not allow water to spill into vacuum motor inlet. Dry spills from top of solution tank. REMOVE SOLUTION FILL COVER Use only the suitable chemicals listed below. Using incompatible chemicals will damage the machine. Damages of this type are not covered under warranty. Carefully read ingredients on manufacturer's label before using any product in this machine.
Operations Pre Run Setup Remove electrical cord and literature from recovery tank. Fill solution tank (see filling instructions). STEP 1 Plug cord into grounded outlet. NOTE: Be sure dome is seated on recovery tank, and float shut-off is installed correctly. STEP 2 Switch the cleaning mode switch to the desired process. Press the top of the switch for the encapsulating Interim Carpet Cleaning Process. Press the bottom of the switch for Deep Extraction.
Operations Lower machine to floor. Select continuous AUTO setting to start solution spray or select intermittent PRESS setting to enable use of trigger switches to start solution spray. MAIN SWITCH The intermittent PRESS setting requires the operator to hold any one of the three trigger switches in the "on" position with the fingers, and is typically used in small areas where short cleaning passes are made.
Operations Operating The Machine 2 1. This machine can be operated in either direction. For smaller areas operate the machine by pulling rearward. 1 For larger unobstructed areas, flip the handle and use the machine's brush assisted propelling motion. STEP 1 2. Start at wall closest to power outlet. For small areas, pull straight back without pushing down on handle. STEP 2 1 ft. (30 cm) 3.
Operations Start at wall closest to power outlet. For large areas flip handle and operate machine in parallel passes, overlapping brush path. Clean perimeter last. ALTERNATE CLEANING PATH VACUUM INTAKE SOLUTION INTAKE STEP 5 5. During operation, observe the following: This machine is equipped with clear dome to facilitate operator viewing of dirty solution and vacuum air flow. During operation, observe the vacuum intake.
Operations To speed drying, use an air mover fan. RECOVERY DRAIN HOSE 8. . Empty recovery tank by releasing recovery drain hose. Use a hose with cold water to clean out the recovery tank. Drain solution tank after each use.
Operations Using The Hand Tool 1. Use only acceptable accessory tools. See Optional Accessories section. To connect solution hose pull back collar and insert over machine mounted fitting, then release collar to lock into place. Solution connection can remain connected at all times. HAND TOOL CONNECTION SOLUTION QUICK DISCONNECT Disconnect vacuum hose and connect the hand tool to hand tool connection as shown. HAND TOOL SWITCH 2. Select hand tool switch. 3.
Maintenance Service Schedule MAINTENANCE Check machine for cord damage Check recovery dome and gasket for damage and cleanliness Check brushes - should be clean with no lint or strings attached Remove bearing cap from end of brush. Clean bearing and cap. Inspect vac shoe for blockage; remove fibers with coat hanger, etc.
Maintenance Components 6 2 4 1 3A LEFT BOTTOM 5 RIGHT 3B 1. Vacuum Motor 2. Solution Strainer (Inside Tank Fitting) 3A. Spray Jet - Extraction 3B. Spray Jet - Interim 4. Interim Solution Pump 5. Main Solution Pump 6.
Maintenance Periodic Maintenance Twice a month, flush a white vinegar solution (One quart vinegar to two gallons of water) or anti-browning solution (mixed as directed) through the extractor. This will prevent build-up of alkaline residue in the system. If spray jets become clogged, remove the spray tips, wash them thoroughly, and blow-dry. 3. After each use, rinse tank with fresh water.
Maintenance Circuit Protection CIRCUIT BREAKERS Circuit Breakers Circuit breakers interrupt the flow of power in the event of an electrical overload. When a circuit breaker is tripped, reset it by pressing the exposed button. If a circuit breaker continues to trip. The cause should be found and corrected. 15 Amp. Protects the vacuum motor. 8 Amp. Protects the brush motor.
Maintenance Scrub Deck 1 3 4 2 1. Scrub Brush Motor 2. Scrub Brushes 3. Retaining Clip 4.
Maintenance Scrub Head Scrub Brush Replacement The dual cylindrical scrub head is designed to scrub chemical into the carpet. The two counter rotating brushes raise the pile of the carpet, giving it a lush groomed appearance. The rear brush is the stiffer brush and is intended to scrub deeper and help propel the machine. It can be identified by its black color. The front brush is the softer brush and is intended to lift and groom the carpet pile. It can be identified by the white bristles.
Maintenance Vacuum Motor Carbon Brushes End Cap Important: These brushes wear quicker as the length shortens due to increased heat. Spring inside brush housing will damage motor if brushes are allowed to wear away completely. Carbon Brushes 3 [9.5mm] 8 Periodically check the length of the carbon brushes. Replace both carbon brushes when either is less than 3/8" (9.5mm) long. The green ground wire must be attached for safe operation. See wiring diagram.
Maintenance Troubleshooting PROBLEM No Power, Nothing Runs Vacuum Motor Will Not Run Vacuum Motor Runs But Suction Is Poor CAUSE Is the cord plugged in. Plug in cord. Circuit breaker tripped in building. Faulty switch. Faulty power cord or pigtail. Reset breaker. Call for service. Call for service. Vacuum circuit breaker tripped. Reset breaker. Faulty main vacuum switch. Loose wiring. Faulty vac motor. Call for service. Call for service. Call for service. Debris lodged in vac shoe.
Suggested Spare Parts 86299250 VACUUM MOTOR 86003630 FLOAT SHUT-OFF 86390390 STRAINER RIGHT 86298070 PUMP BOTTOM 86297440 JET, EXTRACTION 86012550 JET, INTERIM 32 86408790 Operator’s Manual - Clipper Duo 86201110 PUMP
Notes 86408790 Operator’s Manual - Clipper Duo 33
THANK YOU! ! MERCI! DANKE! GRACIAS! Registrieren Sie Ihr Produkt und profitieren Sie von vielen Vorteilen. Register your product and benefit from many advantages. Enregistrez votre produit et bénéficier de nombreux avantages. Registre su producto y aproveche de muchas ventajas. www.kaercher.com/welcome Bewerten Sie Ihr Produkt und sagen Sie uns ihre Meinung. Rate your product and tell us your opinion. Évaluer votre produit et dites-nous votre opinion. Reseñe su producto y díganos su opinión www.