Operating instructions

29
Maintenance
Transportation
If the battery is not installed in equipment, it must be transported in the original package or equivalent.
Batteries are tested according to UN Handbook of Tests and Criteria, part III, sub section 38.3 (ST/SG/AC. 10/11/
Rev.5). For transport, the batteries belong to category UN3480, Class 9, Packaging Group II.
Operating Limits
The battery should not be operated outside these operating limits:
Opera
Do not install batteries in series. Select the appropriate AES battery model for the voltage of your system.
NOTE: Intentional bypassing of BMS to operate battery outside maximum and minimum limits voids warranty.
Fuse
Fuse provides back-up over-current protection.
Fuse Replacement
A blown fuse requires service from a qualified technician. Contact your Discover supplier for more information.
Operating Limits 12-36-6700
Continuous Charge Current 150A
Continuous Discharge Current 150A
Charge Voltage 40.8 V
Operating Voltage (Min / Max) 33.6 V / 43.8 V
Charge Temperature (Min / Max) 0°C / 45°C (32°F / 113°F)
Discharge Temperature (Min / Max) -20°C / 50°C (-4°F / 122°F)
Storage Temperature (Min / Max) -20°C / 45°C (-4°F / 113°F)
8.644-672.0 Operator Manual - Chariot 3 - CV86/1 RS Bp