User Manual

– 10
Note: Once the appliance shuts off, switch it off us-
ing the vacuum button, because the suction turbine
will otherwise start running again once you open
the appliance.
If you use a crevice nozzle:
Attach and secure the adapter for wet/dry vacuum-
ing. Install the crevice nozzle directly to the adapt-
er.
Switch on the vacuum process.
Turn off the appliance.
Drain the full container.
Rinse the reservoir thoroughly with clear water.
Separate handle, spray suction pipes and washing
nozzle, in order to do so, open the locking lever
(central position).
Flush the accessories separately under running
water and let air dry.
Leave the appliance open to let it dry.
Illustration
Accessories storage: Suction hose, suction
pipes and accessories can be comfortably stored
on the appliance.
Storing the appliance. Store the appliance in a
dry room.
With an uneven spray jet.
Illustration
Loosen nozzle attachment and pull out, clean or re-
place spray nozzle.
1 x year or as needed.
Illustration
Clean sieve.
For heavy contamination:
Illustration
Unlock and open the cover, remove flat fold filter,
remove grid and brush off filter.
Fill up fresh water reservoir.
Sieve in the fresh water container clogged.
Thermal protection switch has switched off the
pump as it was overheated. Switch off appliance
and let it cool down (approx. 20 - 30 min).
Detergent pump defective, contact customer ser-
vice.
Clean the spray nozzle of the washing nozzle.
Close the surrounding air separator at the handle.
Accessories, suction hose or suction tubes are
clogged, please remove the obstruction.
Filter bag is full: Insert new filter bag.
Flat fold filter is contaminated, use filter cleaning
mechanism, remove the flat fold filter if heavily
soiled and clean it (see chapter "Cleaning flat fold
filter").
Fill up fresh water reservoir.
Use the correct detergent from KÄRCHER.
Order no. 6.295-771.0 carpet cleaner RM 519.
Plug in the mains plug.
Subject to technical modifications!
Finish operation
Care and maintenance
Clean the spray nozzle
Clean the sieve in the fresh water reservoir
Clean flat fold filter
Troubleshooting
No water exiting from nozzle
Spray stream uneven
Insufficient vacuum performance
Detergent pump noisy
Strong foam generation in the container
Appliance is not running
Technical specifications
Voltage
1~50-60 Hz
220 - 240 V
Output P
nom
1200 W
Output P
max
1400 W
Mains fuse (slow-blow) 10 A
Sound pressure level
(EN 60704-2-1)
77 dB(A)
Weight (without accessories) 7,1 kg
Special accessories
Order No.
Filter set (5 pc.) 6.904-143.0
Flat fold filter 6.414-498.0
Washer nozzle for cleaning uphol-
stery
2.885-018.0
Carpet cleaner RM 519 (1 l bottle)
International 6.295-771.0
Textile waterproofing-agent
Care Tex
RM 762
(0.5 l bottle)
International 6.295-769.0