Operating instructions

Table Of Contents
– 8
DANGER
Only persons trained in waste disposal are
permitted to dispose off the dust collection
container.
Release and remove the suction head.
Illustration
Pull safety filter bag on the flange up
and out.
Close tightly the opening of the suction
connection of the safety filter sack using
the closing lid.
Illustration
Pull over the safety filter sack.
Illustration
Take off the protective film and close
the ventilation hole (1x NT 30/1 - 2x NT
40/1, NT 50/1) with a self-adhesive tab.
Securely close the safety filter bag with
the attached cable tie.
Remove the safety filter bag.
Wipe the inside of the container using a
damp cloth.
Dispose of the safety filter bag in a dust-
tight bag according to the statutory pro-
visions.
Illustration
Pull the new safety filter bag over the
container.
Illustration
Insert the safety filter sack.
Insert and lock the suction head.
Illustration
Release and remove the suction head.
Put the disposal bag over.
Take off the protective film and close the
ventilation hole with a self-adhesive tab.
Tightly close the disposal bag with ca-
ble tie underneath the opening.
Remove disposal bag.
Wipe the inside of the container using a
damp cloth.
Dispose of the disposal bag according
to the local provisions.
Insert the new disposal bag.
Pull disposal bag over the container.
Ensure that the marking line is within
the container and the ventilation hole is
positioned on the back wall of the con-
tainer.
Insert and lock the suction head.
Illustration
Allow device to cool down.
Release the cooling air flaps with
screwdriver and swivel them out.
Clean (vacuum, wash) or replace the
cooling air filter.
Fold in the cooling air flaps and snap
them in place.
Release and remove the suction head.
Clean the electrodes with a brush.
Insert and lock the suction head.
DANGER
First pull out the plug from the mains before
carrying out any tasks on the machine.
Note: In case of a failure (e.g. filter break-
age) the appliance must be turned off im-
mediately. The failure must be remedied
before the appliance is put into operation
again.
Check the receptacle and the fuse of
the power supply.
Check the power cable, the power plug,
the electrodes and the receptacle of the
device.
Turn on the appliance.
Empty the container.
Insert flat folded filter.
Replace the disposal bag
Clean/replace the cooling air filter
Cleaning the electrodes
Troubleshooting
Suction turbine does not run
Suction turbine turns off
25EN