Operating instructions

6English
Troubleshooting guide
Malfunctions often have simple causes that you can
remedy yourself using the following overview. When in
doubt, or in the case of malfunctions not mentioned
here, please contact your authorised Customer Service.
Faults during charging
Battery pack not charging, display is on
Defective charger.
1. Replace the charger.
Battery pack not charging, display is off
Battery pack is completely discharged or defective.
1. Wait and see if the display shows the remaining
charging time after a while.
If the display remains off then the battery pack is de-
fective.
2. Replace the battery pack.
Battery pack not charging, display shows the tem-
perature symbol
The battery pack temperature is too low/high.
1. Put the battery pack in a moderate temperature en-
vironment and wait until the battery pack tempera-
ture returns to the normal range, see the "Technical
data" chapter.
The charging process begins automatically.
Technical data
Subject to technical modifications.
BC 18 V BC 36 V
Electrical connection
Battery pack nominal volt-
age
V18 36
Charging power max. A 2,5 2,5
Battery pack type Li-ION Li-ION
Battery platform Battery
Power /
Battery
Power+
Battery
Power /
Battery
Power+
Mains voltage V 100 -
240
100 -
240
Frequency Hz 50 - 60 50 - 60
Current consumption A 1,5 1,5
Protection class II II
Dimensions and weights
Weight (without battery
pack)
g 160 160
Permissible temperature
range during charging pro-
cess
°C 4 - 40 4 - 40
Length x width x height mm 184 x
133 x 87
Length x width x height mm 184 x
133 x 87