Operating instructions

– 11
Warning
Do not screw the safety lock on the appliance
during the decalcifying.
Do not use the steam cleaner as long as there is
decalcifying agent in the boiler.
Completely empty the descaling solution af-
ter 8 hours. A small amount of the solution
will remain in the boiler. Therefore, you
should rinse the boiler two to three times with
cold water to remove any residues of the
descaler.
Completely empty the steam boiler to re-
move existing water (see fig. ).
Note: The floorcloth and the terry cloth cover
have been pre-washed and can be used imme-
diately for working with the steam cleaner.
You can wash dirty floorcloths and terry cloth
covers in the washing machine at 60°C. Do
not use a liquid softener as this would affect
the ability of the cloths to pick up dirt. You
may tumble dry the cloths.
Often, failures have simple causes and you can
do the troubleshooting yourself using the follow-
ing overview. If you are in doubt or if the failure is
not listed here please contact the authorized
customer service.
Danger
Always disconnect the mains plug and allow the
steam cleaner to cool down before performing
any maintenance work.
Repair works may only be performed by the au-
thorized customer service.
Descale the steam boiler.
Turn off the appliance.
See „Refilling Water“ Page 9.
Steam switch is secured with the lock / child-
proof lock.
Move the selector switch for the steam vol-
ume to the front.
Press the steam gun until less water is emitted.
Descale the steam boiler.
Subject to technical modifications!
Care of the Accessories
Troubleshooting
Long heating-up time
Steam boiler is decalcified
No steam
No water in the steam boiler.
Steam lever cannot be pressed anymore
High water output
Steam chamber too full
Steam boiler is decalcified
Technical specifications
Power connection
Voltage 220-240
1~50/60
V
Hz
Protective class I
Protection class IPX4
Performance data
Heating output 1500 W
Operating pressure max. 0,32 MPa
Heating time 8 Minutes
Steam volume
Continuous steaming 40 g/min
Steam push max. 100 g/min
Dimensions
Boiler capacity 1,0 l
Weight (without accessories) 3,1 kg
Width 254 mm
Length 380 mm
Height 260 mm
18 EN