Operating instructions

- 5
Technical specifications
HKF 200 E
(3x400V)
HKF 200 E (3x42V) HKF 200 ET
Order No. 4.631-002 4.631-000 4.631-003
Max. flow rate l/h (l/min) 10000 (167) 10000 (167) 10000 (167)
Max. flow rate with solvent operation l/h (l/min) 3000 (50) 3000 (50) 3000 (50)
Max. temperature with water with cleaning agents °C 95 95 95
Max. temperature with solvents, brines, acids °C 20 20 20
Max. operating pressure MPa (bar) 20 (200) 20 (200) 20 (200)
Max. operating pressure with solvent operation MPa (bar) 5 (50) 5 (50) 5 (50)
Voltage V 230/400 42 230/400
Current type -- 3~ 3~ 3~
Frequency Hz 50 50 50
Rated power W 120 120 120
Functional speed - drive 1/min 19 19 19
Sound pressure level (EN 60704-1) dB(A) 70 70 70
High pressure connection -- DN 15 - M22x1.5 DN 15 - M22x1.5 DN 15 - M22x1.5
Minimum container opening mm 200 200 140
Length including bow to nozzle center mm 1415 1415 1115
Standard immersion depth mm 800 800 500
Weight kg 40 40 38
Ambient temperature °C +2...+40 +2...+40 +2...+40
Ignition protection class II 1/2 G c IIB T3 X
+2 °C
< Ta < +40 °C
20 EN