Quick Start Manual

QUICKSTART
5.964-039.0 02/11
Troubleshooting
1
A
D
B
E
C
F
Appliance cannot be started
A Step on the standing platform.
Do not press the accelerator pedal.
B Release emergency-stop button by turning.
C Set main switch to “1”.
D Unplug the charger from the mains.
E Battery depleted.
Charge battery.
F Close the solenoid brake. To do this, press
the lever of the solenoid brake all the way up
to the stop.
2
A
B C
Device does not drive or drives only slowly
A Release accelerator pedal, turn the key
switch to "0", turn the key switch to "1", press
the accelerator pedal.
B Reset fuse of control system.
C Battery depleted.
Charge battery.
3
A
D
G
B
E
C
F
No or inadequate suction power
A Empty the dirt water reservoir.
B Reset fuse of suction turbine.
C Clean the seals between dirt water reservoir
and top of the appliance and check for leaks,
replace if required.
D Clean the vacuum lips on the vacuum bar,
turn or replace if required
E Check suction hose for blockages; clean if
required.
Check connection between suction hose and
suction bar and suction hose and wastewater
tank.
F Clean the floater in the dirt water tank.
G Check and clean the waste water reservoir
sieve.