Operating instructions

Operating Instructions English
6
Warning!
Rupture hazard!
Additional pumping leads to
exceeding the maximum
permissible pressure of 3 bar.
The cleaning agent is applied
by actuating the spray lever.
Releasing the spray lever
terminates spraying.
Cleaning the spray bottle
Note:
Prior to using a different cleaning
agent or every time after it ha s
been used it is necessary to
discharge the pressure in the
spray bottle and to clean i t.
Warning!
Hold a suitable container beneath
the nozzle, since cleaning agent is
sprayed out of the nozzle when
the spray lever is ac tuated.
To allow high excess pressure
to escape from the spray bottle
actuate the spray lever until the
high pressure is relieved.
To discharge low overpressure
in the spray bottle unscrew it
carefully from the spray unit .
Clean the bottle a s instructed in
compliance with the safety
notes.
Dispose of the bottle’s residue
liquid according to regulations.
Fill the bot tle with clean water.
Warning!
The bottle may only be filled with a
maximum of 1 litres of liquid.
Screw the spray unit a irtight
back onto the bottle.
Pressurize the spray bottle with
a maximum of 15 pumping
actions.
Warning!
Rupture hazard!
Pumping more leads to exceeding
the maximum permissible
overpressure of 3 bar.
Warning!
Hold a suitable container beneath
the nozzle, since cleaning agent is
sprayed out of the nozzle when
the spray lever is actuated.
Actuate the spray lever until all
the pressure has been relieved.
Unscrew spray unit from the
bottle.
Clean the bottle a s instructed in
compliance with the safety
notes.
Dispose of the bottle’s residue
liquid according to regulations.