WTC 600 LP / MP Contents 1 2 3 3.1 3.1.1 3.1.2 3.1.3 3.1.4 3.2 3.2.1 3.2.2 3.2.3 3.2.4 3.2.5 res 3.2.6 3.3 Safety Notes...........................................3 Intended Use ..........................................3 Maintenance and Care ...........................4 Starting Operation ..................................4 Admission-pressure Unit ........................4 Filling the Metering Stations ...................4 Switching On the Equipment ..................5 Operating Indicators ...............
Maintenance and Care 3 WTC 600 LP / MP Version 06/05 Maintenance and Care The equipment may be put into operation only when set-up, installed and prepared for operation by an authorized KÄRCHER specialist dealer. 3.1 Starting Operation Before starting operation: • Make sure that the equipment is connected to the untreated water source and the respective transporting gear, e. g., admission-pressure unit.
WTC 600 LP / MP Version 06/05 Maintenance and Care If the metering container was completely empty, the metering pump (29) may have possibly drawn in air. In this case, bleed the air from the pump as described in Section 3.2.3. 3.1.3 Switching On the Equipment • Check if the pumps of the metering station, sand and activated carbon filter are connected to the respective power outlets (18 / 19) at the switch box (8).
Maintenance and Care 3.2 Version 06/05 WTC 600 LP / MP During Operation Drinking water quality is ensured only when the following control intervals are met. In case deviations from the desired condition can not be eliminated through the measures mentioned, the drinking water production must be stopped and the Kärcher Service must be notified. 3.2.
WTC 600 LP / MP Maintenance and Care Version 06/05 • After a while the indication moves back to the current time. • Screw in the bleeding screw again. production / production produccion / produzione fault / default error / guasto disinfection / nettoyage desinfeccion / disinfezione reject / rejet evacuation / evacuatione regeneration / regeneration regeneracion / rigenerazione tank full / stockage plein deposito lleno / serbatoto pieno 32 3.2.
Maintenance and Care • Before screwing on the filter bowl, check the sealing ring (39) for damage. • Screw on the filter bowl and tighten with the filter wrench. • Open the untreated water supply again and start the system with the main switch. 3.2.5 The system reacts somewhat timedelayed to alterations of the regulation valves.
WTC 600 LP / MP Notice: The amount of concentrate will increase. This is correct. Observe the maximum pressure of 21 bar (MP) or 14 bar (LP) at the manometer (11)! • Repeat the adjustment steps, if required. The original drinking water amount may possibly not quite be reached. pressure (12), and determine the differential pressure. • Compare the differential pressure with the value taken when starting operation (see operational start-up record).
Consumption Materials (2) Metered Addition For mixing of the chemical, only unchlorinated drinking water may be used. This water is taken from the drinking water sampling valve (44). 44 The metered addition is carried out dependent of the level in the metering container. Completely emptied metering container: • Fill 10 l of drinking water into the metering container. • With a measuring cup, measure the 7.
WTC 600 LP / MP 5 Malfunctions Version 06/05 Malfunctions Malfunctions of the RO system are signaled with LEDs at the control panel (10) and indicated at the display. i In case of a malfunction, the system is generally switched off and the drinking water production is interrupted. If the malfunction can not be corrected, stop the drinking water production and notify the Kärcher Service.
Technical Data 6 WTC 600 LP / MP Version 06/05 Technical Data Parameter WTC 600 LP Ambient temperature +1 °C – +50 °C Storage temperature (upon delivery) to –10 °C Humidity <100 % r.F. 3*400 V 50 Hz * 1*230 V 50 Hz * Supply voltage Pre-filter controls: prim./sec. Metering pumps WTC 600 MP 230 V/12 V 50 Hz 220 – 240 V 50 – 60Hz Electrical protection 16 A Connected load 2.2kW 2.2 kW Effective power consumtion 1.5 kW 2.
WTC 600 LP / MP 7 Version 06/05 EU Declaration of Conformity EU Declaration of Conformity We hereby declare that the equipment described below conforms to the relevant fundamental safety and health requirements of the appropriate EU Directive, both in its basic design and construction as well as in the version marketed by us. This declaration will cease to be valid if any modifications are made to the machine without our express approval. Product: Water treatment plant Model: 1.