Manual

- 4
Insert the vacuum bar into the vacuum
bar suspension in such a manner that
the profiled sheet is positioned above
the suspension.
Tighten the wing nuts.
Insert the suction hose.
Check if the height adjustment is
mounted on the inside of the vacuum
bar.
When the height adjustment is mounted
on the outside, the vacuum bar gets
caught at the bottom of the appliance.
Danger
Risk of injury. Pull the Intelligent Key to take
all functions out of operation immediately.
Insert batteries and connect (see "Be-
fore Start-up").
Place long lateral boards of the packag-
ing as a ramp next to the pallet.
Fix the ramp on the pallet with nails.
Place short boards as a support under-
neath the ramp.
Remove the wooden bars in front of the
wheels.
Plug in the Intelligent Key.
Turn the program selection switch to
transport mode.
Press the driving lever and slowly move
the machine down from the ramp.
Remove the Intelligent Key.
Danger
In dangerous situations, release the drive
lever.
Loosen the parking brake; for that press
the pedal downward and move it to the
left. Then let the pedal go upward.
Activate immobilising brake. Press the
pedal downwards and move it to the
right to lock it.
Note
The machine is designed in such a way that
the brush head protrudes on the right. This
helps in working in a proper way even close
to the edges.
Plug in the Intelligent Key.
Preselect the speed on the drive speed
rotary knob.
Turn the programme selection switch to
transport mode.
Release parking brake.
Drive the machine.
Forwards:
Press the driving lever to the front.
Backward:
Press the driving lever to the rear.
Note
The machine moves only when the driving
lever is moved by 15°.
Stop the machine: Release driving lever.
Open the lock of the fresh water reser-
voir.
Fill fresh water (maximum 60 °C) until
the lower edge of the filling nozzle.
Close the lock of the fresh water reservoir.
With automatic fill of fresh water reser-
voir (option)
Connect the hose to the automatic fill-
ing system and open the water supply
(max. 60 °C, max. 5 bars).
Monitor the appliance - the automatic
filling system will interrupt the water
supply when the tank is full.
Shut off the water supply and discon-
nect the hose from the appliance.
Warning
Risk of damage. Only use the recommend-
ed detergents. With respect to different de-
tergents the operator bears the increased
risk regarding the operational safety and
danger of accident.
Only use detergents that are free from sol-
vents, hydrochloric acid and hydrofluoric
acid.
Follow the safety instructions for using de-
tergents.
Note
Do not use highly foaming detergents.
Recommended detergents:
Detergent is added to the fresh water on
the way to the cleaning head with the help
of a dosaging device.
Note
The metering device can be used to add
3% of detergent at maximum. In case of a
higher dose the detergent must be poured
into the fresh water tank.
Place the detergent bottle into the hold-
er.
Close the bottle lid.
Insert the suction hose of the dosaging
equipment into the bottle.
Note
If the fresh water tank is empty, then the
function of adding detergent gets deactivat-
ed. The cleaning head continues to work
without the addition of any liquid. Detergent
addition is also stopped when the detergent
can is empty.
Add the detergent to the fresh water
reservoir.
Adjust the water quantity using the reg-
ulating button according to the dirt on
the floor covering.
Note
Carry out the initial cleaning attempts with
little quantities of water. Increase water
quantity step-by-step until the desired
cleaning result is achieved.
The detergent pump of the dosing equip-
ment does not start working until a mini-
mum water volume is present.
Installing the Vacuum Bar
Unloading
Operation
Parking brake
Driving
Filling in detergents
Fresh water
Detergent
Application Detergent
Routine cleaning of all wa-
ter resistant floors
RM 746
RM 780
Routine cleaning of glossy
surfaces (e.g. granite)
RM 755 es
Routine cleaning and basic
cleaning of industrial floors
RM 69 ASF
Routine cleaning and basic
cleaning of fine stoneware
tiles
RM 753
Routine cleaning of tiles in
sanitary areas
RM 751
Cleaning and disinfection in
sanitary areas
RM 732
Removal of coating from all
alkali-resistant floors (e.g.
PVC)
RM 752
Removal of coating from li-
noleum floors
RM 754
Appliance with dosing equipment DOSE
(option)
Models without dosing equipment
Setting the water quantity
9EN