Manual
- 21 -
C145300602.fm
English
Maintenance information
GB
R750
Maintenance during running-in table (first 50 hours)
Important
For each maintenance operation, fill in
the "Periodic maintenance operation
record sheet" provided, so as to keep a
trace of the operations performed and
therefore establish the most suitable
methods for future operations.
Routine maintenance table (after running-in)
Important
For each maintenance operation, fill in
the "Periodic maintenance operation
record sheet" provided, so as to keep a
trace of the operations performed and
therefore establish the most suitable
methods for future operations.
Frequency
(1)
Component Type of intervention Intervention procedures Reference
Every
10 hours
(every day)
Engine oil
(2)
Level control Top up, if necessary
See "Engine oil level
control"
Coolant
(4)
Level control Top up, if necessary
See "Engine coolant
level check"
Air filter Check it is clean
Clean with low pres-
sure compressed air.
Replace, if necessary
Coolant fluid radia-
tor
Check it is clean Clean with a soft brush
After the first
50 hours (at
the end of
running-in)
Oil filter Replacement
See "Oil filter cartridge
replacement"
Frequency
(1)
Component Type of intervention Intervention procedures Reference
Every
10 hours
Engine oil
(2)
Level control Top up, if necessary
See "Engine oil level
control"
Coolant
(4)
Level control Top up, if necessary
See "Engine coolant
level check"
Air filter Check it is clean
Clean with low pressure
compressed air.
Replace, if necessary
Coolant fluid radia-
tor
Check it is clean Clean with a soft brush
Every
300 hours
Engine oil
(2)
Replacement
See "Engine oil
change"
Oil filter
Replace the car-
tridge
See "Oil filter car-
tridge replacement"