Operation Manual

– 9
Type HD 5/12 C
1.514-110.0
HD 5/12 C
1.514-105.0
HD 5/12 CX
1.514-554.0
HD 5/12 CX
1.514-553.0
GB KAP, 60Hz AU
Main Supply
Voltage V 240 220 240
Current type Hz 1~ 50 1~ 60 1~ 50
Connected load kW 2,3
Protection (slow, char. C) A 10 16 10
Type of protection IPX5
Extension cord 30 m mm
2
2,5
Water connection
Max. feed temperature °C 60
Min. feed volume l/h (l/min) 600 (10)
Suck height from open container
(20 °C)
m 0,5
Max. feed pressure MPa (bar) 1 (10)
Performance data
Working pressure MPa (bar) 11,5 (115) 12 (120) 11,5 (115)
Nozzle size 034 036 038
Max. operating over-pressure MPa (bar) 15 (150)
Flow rate l/h (l/min) 510 (8,5) 500 (8,3) 510 (8,5)
Detergent suck in l/h (l/min) 0...35 (0...0,6)
Max. recoil force of hand spray gun N 21
Values determined as per EN 60355-2-79
Hand-arm vibration value
Hand spraygun m/s
2
2,5 <2,5 2,5
Spray lance m/s
2
<2,5
Uncertainty K m/s
2
1
Sound pressure level L
pA
dB(A) 74
Uncertainty K
pA
dB(A) 2
Sound power level L
WA
+ Uncertainty
K
WA
dB(A) 89
Fuel
Amount of oil l 0,35
Oil grade -- SAE 15W40
Dimensions and weights
Length mm 360
Width (CX) mm 375 (400)
Height mm 925
Weight without accessories (CX) kg 22 (27)
25EN