Owners Manual 1400JF & 1400JFL Aerating Fountain Contents Safety General Instructions Parts & Tools Assembly & Installation Options & Pattern Sizes C-25 Timer Control Maintenance Recommendations Warranty Troubleshooting Tips Replacement Parts Diagram Customer Repair Form Registration Information C Intertek 3020379 ANSI/UL 778, 5th Ed. 2010 CAN/CSA C22.2 No. 108-M89 UL 50, 11th Ed. 1995 Kasco Marine, Inc. 800 Deere Rd. Prescott, WI 54021 PH (715) 262-4488 FAX (715) 262-4487 www.kascomarine.com . . . .
Thanks We at Kasco Marine, Inc. would like to both thank and congratulate you on your purchase of the 1400JF Aerating Fountain. We appreciate you choosing Kasco and for your purchase. Your decision to purchase Kasco’s 1400JF Aerating Fountain will not disappoint you. The 1400JF Aerating Fountain will be a great addition to your body of water. It will help improve the water quality by adding much needed oxygen and circulation.
cal cord. Always use extreme caution around electrical equipment and water situations. ASSEMBLY & INSTALLATION Please see the proper Assembly and Installation Instructions enclosed in this manual. Each is specific for your model and size of Fountain. Note: Use the nylon tie provided to help keep the power cords for the unit and lights free of the propeller by tying the cords and one of the mooring ropes together.
UNIT SPECS Model Voltage 1400JF 120 volts Amps 3.
STEP THREE Locate the 5 nozzles included with the shipment (the Osprey nozzle is already installed on the fountain, along with the Upper Pump Housing). Using the Nozzle Options diagram on page 7, determine which pattern is desired and the corresponding nozzle. If the Condor or Falcon patterns are desired, you must remove the Osprey Nozzle by removing the 1” Self Tapping Phillips Head Screw.
STEP SIX Use the ropes to position the Fountain in the desired location in the pond/lake. Anchor the ropes or secure them to the shoreline so the ropes are free of slack, but not tight. To prevent twisting of the unit due to torque, you should place the anchor at least 3 feet from the float for each foot of depth (Ex. A 3 foot deep pond would require an anchor 9 feet horizontally from the float.
STEP NINE Set C-25 Timer to desired ON and OFF times per the C-25 Instructions on page 8. Make sure to test the GFI using the Test Button located on the outlet before turning the equipment on and every 30 days thereafter. Plug the 1400JF cord into the C-25 outlet labeled “UNIT”. If lights are included, plug the Transformer cord into the C-25 outlet labeled “LIGHT”. STEP TEN Plug the C-25 into the 120V power supply on post and ENJOY YOUR NEW KASCO 1400JF AERATING FOUNTAIN.
Eagle’s Nest: Produces a wide “V” pattern of water 3.5 feet high by 10 feet in diameter. This nozzle does not use the upper pump housing. It has the number 4 molded near the screw collar of the nozzle. Hawk’s Nest: Produces a narrow “V” pattern of water 3 feet high by 7 feet in diameter. This nozzle does not use the upper pump housing. It has the number 5 molded near the screw collar of the nozzle. Upper Pump Housing: Must be installed and used with the Osprey, Condor, and Falcon nozzles.
CONTACT A QUALIFIED SERVICE TECHNICIAN! Failure to use the C-25 with Kasco Fountains will void the warranty and cause the Fountain to not be listed to UL and CSA standards via ETL. The following maintenance procedures can be utilized to ensure many years of quality performance from your Kasco Fountain and reduce the need for more costly repair work. PROPER INSTALLATION: Proper installation of Kasco equipment will include a power source with ground fault interruption.
WINTER STORAGE: In regions where there is significant freezing in the wintertime, the fountains should be removed from the water to protect them from the expansion pressure of the ice. In many areas, fountains will keep some amount of ice open through the winter. However, when the water is thrust into the air, it is exposed to the colder air temperatures longer and can actually make ice thicker on the pond/lake. Storage over winter is best in a location that is out of the sun and cool, but above 32OF.
The Fountain is returned for repair without the power cord or if the unit, control box, or power cord are altered in any way from original shipment. Cuts in the power cord are not covered under warranty. Fountain must be connected to the supplied GFI control box to be covered under warranty. The Fountain is damaged by unauthorized tampering.
ahead before sending in a repair. Kasco Marine does estimates on repairs at the request of the customer. The request for estimate should be included in the letter that accompanies the returned unit and must include a daytime phone number and/or e-mail address. Estimate options are as follows: We will contact the customer with a total after the unit has been evaluated, but before the work is performed. We will repair the unit only if repair costs are under a stated dollar amount.
“My Fountain hums, but will not start. When I spin the prop with a stick, it starts up.” This indicated a problem with the Starting Capacitor. Each Kasco Fountain is equipped with a Starting Capacitor to get the unit going when it is first plugged in. If it is operating, but not spinning and can be started by spinning the prop with a stick, the Starting capacitor needs to be replaced by an Authorized Repair Center.
Replacement Parts Diagram ITEM NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 PART NO. 140012 140412 140112 140312 140512 140910 258476 144314 475630 840536 840537 334306 144100 142212 990600 990400 990280 990285 140925 443154 990275 181625 140711 22 8 DESCRIPTION 1 1 1 3 1 1 6 3 3 3 3 4 1 1 1 1 1 1 1 1 1 1 1 QTY 2 FLOAT, 1400 SERIES LIGHT RING ASSEMBLY PUMP HOUSING, LOWER RETAINING CLIP UPPER PUMP HOUSING CAN, 1400 SERIES FLAT WASHER, 1/4" 1/4-20 X 3.
800 Deere Rd. Prescott, WI 54021 Phone: 715-262-4488 - Fax: 715-262-4487 www.KascoMarine.com Sales@KascoMarine.com Customer Repair Form * Important Reminders * • All repairs sent in MUST be accompanied by a copy of this completed sheet! • Routine maintenance consists of keeping the unit clean, keeping the stainless steel can clean, and having the seals and oil replaced every 3 years depending on use. • Address your Repair to Kasco Marine, Attn: Repairs (or to your Authorized Repair Center).
Registration Information Please register your fountain online at: www.kascomarine.com Also fill in the information below and keep for your records. Model # (Ex. 1400JF)_______________________________ Serial # (Ex. 7001J141725)______________________________ Purchase Date:_____________________ Purchased From:___________________________________ Registration Date: ___________________________ Kasco Marine, Inc. 800 Deere Rd. Prescott, WI 54021 Phone (715) 262-4488 • Fax (715) 262-4487 www.kascomarine.