Owners Manual J Series Fountains 8400JF, 3.1JF 2.3JF, 3.3JF 2.3HJF, 3.3HJF Kasco Marine, Inc. 800 Deere Rd. Prescott, WI 54021 PH (715) 262-4488 kascomarine.
Table of Contents Important Safety & Additional Notes pg 2-3 Tools and Supplies Needed, Unit Specs pg 3 Parts, Nozzles Included pg 4 – 5 Optional Premium Nozzles pg 6 Assembly Instructions pg 7 – 9 Nozzle Installation Instructions pg 10 Unit Installation Instructions pg 11 3-Phase Startup Procedure pg 12 Maintenance pg 13 Warranty pg 14 Repair pg 15 Troubleshooting Tips pg 16 – 17 Replacement Parts pg 18 – 19 Repair Contact Form pg 21 Important Safety: Please read and follow thes
• • • • Extreme caution should be used around water, especially cold water, as in Spring, Fall, and Winter, which poses a hazard in and of itself. NEVER lift or drag the equipment by the power cords. If you need to pull the unit to the side of the pond, use the anchoring ropes. Do not use boats that tip easily for installation and follow all boating safety rules and regulations, including wearing a PFD (Personal Flotation Device).
Parts Included Unit Size 2hp 3hp 5hp 7hp Voltage/Phase G (PartNo) 208-240/1φ 8400JF 208/3φ 2.3JF 460/3φ 2.3HJF 208-240/1φ 3.1JF 208/3φ 3.3JF 460/3φ 3.3HJF 208-240/1φ 5.1JF 208/3φ 5.3JF 460/3φ 5.3HJF 208/3φ 7.3JF 460/3φ 7.
Nozzles Included Note: The Birch nozzle is preinstalled on the unit from the factory. *Pattern sizes listed are approximate. Variations in voltage caused by regional electrical differences or voltage drop due to long power cords may result in reduced pattern sizes.
Optional Premium Nozzles (not included) Premium nozzles are not included as standard but may be added and installed at any time. These nozzles offer unique patterns that truly showcase your pond or lake. Contact Kasco Marine at sales@kascomarine.com or your local distributor for order information. *Pattern sizes listed are approximate. Variations in voltage caused by regional electrical differences or voltage drop due to long power cords may result in reduced pattern sizes.
Assembly Instructions Step 1 Place the float (D) over the unit assembly (G). Ensure the three channels on the inside of the float line up with the threaded holes in the baseplate, and the Kasco logo on the top side of the float lines up with the power cord on the unit assembly. This will allow the power cord to run in the power cord channel on the underside of the float later.
Step 3 On the underside of the float, start threading the (3) 3/8 – 16 x 1/2’’ serrated hex head screws (I), but do not tighten down at this time. Leave Gap Step 4 Lift the unit and slide the bottom float screen (H) over the can and up to the bottom of the float, allowing the unit power cord to exit between them in the dedicated channel.
Step 5 Twist the screen clockwise (as viewed from the bottom) so that the flanges in the screen grab the serrated hex head screws. Tighten all three serrated hex head screws to secure the screen to the bottom of the float, being sure not to pinch the power cord. 9/16’’ side of wrench tool required. Tighten all 3 screws to secure float screen Step 6 Using included cable ties (L), attach the unit power cord to one of the rope holes for strain relief as shown below.
Nozzle Installation Instructions After removing the current nozzle and ensuring that the nozzle O-ring (F) is properly seated in its groove, twist the selected nozzle (E) clockwise (as viewed from the top) so that the flanges in the nozzle lock into place on the top of the pump chamber by hand. Twist until the nozzle flanges can move no further and are completely snug. Nozzles can be changed conveniently without removing the float or using any tools.
Unit Installation Instructions Note: Before installing 3-phase units (2.3JF, 3.3JF, 5.3JF, 7.3JF, 2.3HJF, 3.3HJF, 5.3HJF, 7.3HJF) into the pond, please refer to 3-phase startup procedure on page 12. Use ropes to position the fountain in the desired location in the pond or lake. Anchor the ropes or secure them to the shoreline so that they are free of slack, but not tight. To prevent twisting of the unit due to motor torque, place the anchor at least 3 feet from the float for each foot of depth (Ex.
3-Phase Startup Procedure For 3-Phase Units: 3-Phase Startup Procedure If a Kasco Control Panel is not provided, please refer to the following warnings: When inherent overheating protection is not provided: use with approved motor control that matches motor input in full load amperes with overload element(s) selected or adjusted in accordance with control instructions.
Maintenance Recommendations Under NO CIRCUMSTANCE should anyone enter the water while a fountain is operating. The following maintenance procedures can be utilized to ensure many years of quality performance from your Kasco equipment and reduce the need for more costly repair work. PROPER INSTALLATION: Proper installation of Kasco equipment will include a power source with ground fault protection.
Warranty Warranty Policy Warranty period: 8400JF, 2.3JF, 2.3HJF = 3-year Limited Warranty 3.1JF, 3.3JF, 3.3HJF, 5.1JF, 5.3JF, 5.3HJF, 7.3JF, 7.3HJF = 5-year Limited Warranty Kasco® Marine, Inc. warrants this aerator to be free from defects in material or workmanship under normal use and service (excluding ropes, power cord, and propeller). The Kasco Marine, Inc.
Repair Note: Only complete motor assemblies will be accepted for warranty repair. The power cord and all other components must be returned with the motor as originally assembled. Any missing parts will be replaced at the customer’s expense and, if determined to have caused the failure, could void the entire warranty. Some parts are essential for structural support during shipping and others, such as the power cord, are essential to properly diagnose potential causes of failure.
Troubleshooting Tips The following is provided to help diagnose a probable source of trouble. It is a guideline only and may not show all causes for all problems. For additional troubleshooting help, contact your local distributor or visit kascomarine.com for additional guidance. Note: you may need to refer to your owners manual that was provided with your control panel for additional control panel settings and adjustments. “ My pattern is crooked or does not look even.
prop that is causing the unit to wobble and not pump properly. When the unit is unplugged, check the prop for damages and replace if damage is found. “The GFI breaker trips randomly and sporadically. Sometimes it is a few hours of operation, other times it can be days or weeks.” This is referred to as a Nuisance Trip. This usually occurs where the unit is installed a great distance from the initial electric service on the property where the ground stake is placed.
Unit Replacement Parts 18
Nozzle Replacement Parts Kit 284302 (2HP & 3HP Large J, includes bottom screen 284101) Kit 284305 (5HP & 7.
800 Deere Rd Prescott, WI 54021 Phone: 715‐262‐4488 Fax: 715‐262‐4487 www.Kascomarine.com Sales@kascomarine.com Repair Contact Form ❖ Kasco requires all Repairs sent in MUST be accompanied by this form and marked to Repairs attention. (ex. Attn: Repairs) ❖ Repairs returned should include upper pump housing or wire basket for Aerators and De‐Icers. These parts protect the motor during shipping. ❖ Kasco is NOT responsible for shipping damage accrued in return shipment.