Product Manual
4
Cord Gauge Chart
Length Gauge 3400 3400H
4400H
4400
50’ 16 x
50’ 14 x x
100’ 14 x x
100’ 12 x
150’ 12 x x
150’ 10 x
200’ 12 x x
200’ 10 x
250’ 12 x
300’ 12 x
400’ 12 x
Unit Specs
Model Voltage Amps Lock
rotor
amps
Control
box con-
nection
Fountain
connec-
tion
3400JF 110-120 6.7 18 C-25
plug in
Plug into
C-25
3400HJF 208-240 3.3 9 Hardwire
C-85
plug into
or hard-
wire C85
4400JF 110-120 10.7 40 C-25
plug in
Plug into
C-25
4400HJF 208-240 5.3 20 Hardwire
C-85
plug into
or hard-
wire C85
Parts Included
# Item Part# Qty
1 Fountain 1
2 Float 242001 1
3 1/4-20 x 4” Phillips Pan Head
Screw
251220 4
4 1/4” split washers 840537 7
5 1/4” (3/4” OD) Flat Washer 251300 10
6 1/4 -20 x 1-3/4” Hex Head Bolt 475630 3
7 Bottom Screen Section 361540 3
8 1/4”-20 Nut 840536 3
9 #8 nut 771034 6
10 #8 at washer 361543 12
11 #8 lock washer 771033 6
12 #8 x 3/4” screw 361545 6
Mooring ropes 990700 2
cable ties 415038 9
2
1
7
1110
3
4
5
5
4
8
9 12
6
5
DWG. NO.
XXXX-XXXX-XX
DO NOT SCALE DRAWING
C.A.D. GENERATED DRAWING
800 DEERE ROAD
PRESCOTT, WI 54021-1241
X
X
X
X
X
THIS DRAWING CONTAINS PROPRIETARY
INFORMATION AND SHALL NOT BE USED,
REPRODUCED OR DISTRIBUTED WITHOUT
THE PRIOR WRITTEN CONSENT OF
KASCO MARINE, INCORPORATED
.X
.02 [.508] .XX
.010 [.254]
.XXX
.005 [.127] ANGULAR
0.5
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN INCHES.
DIMENSIONS IN [ ] ARE MILLIMETERS.
TOLERANCES ON:
THIS DOCUMENT HAS BEEN ISSUED
FOR ENGINEERING INFORMATIONAL
PURPOSES ONLY. ANY REVISIONS
TO THE CONTENT OF THIS DOCUMENT
MUST BE INCORPORATED INTO THE
ORIGINAL CAD FILE.
THIRD ANGLE PROJECTION
TITLE:
XXXX-XXXX-XX
SHEET 1 OF 1
FINISH:
MATERIAL:
SCALE: 1:20
from hard water deposits and/or algae.
(See Maintenance Recommendations.)
It is extremely important that proper and sufcient
voltage (120V or 240/208V) is supplied to the Foun-
tain motor. Each 120V Fountain is supplied with a UL
and CSA approved C-25 GFI Protected Control Box.
The Fountain is to be plugged into the C-25 outlet
labeled “UNIT” and the C-25 plugged into a properly
grounded receptacle (See C-25 Instructions on page
12). Each 240V Fountain is supplied with a UL and
CSA approved C-85 GFCB Protected Control Panel.
The Fountain is to be hardwired into C-85 panel. The
C-85 must have 4 wire service (L1, L2, neutral, and
ground) installed by a qualied electrician. (See Wir-
ing Instructions). It is extremely important to test the
GFI breaker in the control panel upon each installation
and reinstallation and every month thereafter to ensure
proper operation.
UNIT STORAGE
When storing units during the offseason, it is impor-
tant to store them upside down if they are going to be
sitting for long periods of time. Units that sit upright
on a shelf for many months, or even years have a
greater likelihood of seals drying out. Storing upside
down will ensure oil is lubricating the seals and pre-
vent drying.
DWG. NO.
3400J SERVICE
DO NOT SCALE DRAWING
C.A.D. GENERATED DRAWING
800 DEERE ROAD
PRESCOTT, WI 54021-1241
X
3400J SERVICE PRINT
X
NONE
X
AS NOTED ABOVE
THIS DRAWING CONTAINS PROPRIETARY
INFORMATION AND SHALL NOT BE USED,
REPRODUCED OR DISTRIBUTED WITHOUT
THE PRIOR WRITTEN CONSENT OF
KASCO MARINE, INCORPORATED
.X
.02 [.508] .XX
.010 [.254]
.XXX
.005 [.127] ANGULAR
0.5
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN INCHES.
DIMENSIONS IN [ ] ARE MILLIMETERS.
TOLERANCES ON:
THIS DOCUMENT HAS BEEN ISSUED
FOR ENGINEERING INFORMATIONAL
PURPOSES ONLY. ANY REVISIONS
TO THE CONTENT OF THIS DOCUMENT
MUST BE INCORPORATED INTO THE
ORIGINAL CAD FILE.
THIRD ANGLE PROJECTION
TITLE:
3400J SERVICE
SHEET 1 OF 1
FINISH:
MATERIAL:
SCALE: 1:20