Config Guide

98 of 122
Operating the Reader Using the ReaderStart Software
14.8.3 Change Reader Parameter
Change reader parameter
allows to change all reader settings using their respective configuration IDs.
4
6
1
2
4 5
3
Fig. 59: Expert settings 2: change reader parameter
Parameter ID
selects the parameter ID
Parameter value
shows or sets the parameter value
The value is either decimal or hexadecimal, it is possible to switch between
dec
and
hex
.
Active parameter
set
shows the current active parameter set
Get
reads the value of the current parameter set of the reader and shows it at
Set
writes the parameter value () into the selected parameter ID ()
14.8.4 Select Filter Settings
By means of these settings, it is possible to filter certain tags, e.g. to only read tags with the defined data in the respec-
tive memory banks. It is possible to set up to 32 filters.
7
8
9
10
11 12
2
4 5
1
2
3
4
5 6
Fig. 60: Expert settings 2: select filter settings
Filter
selects a filter
Target
selects the tag target session
Make sure the target matches the session set in
Fig. 57,p.97
.
Action
selects the action; see also
EPCglobal Gen 2 Specification
(p. 73)
Tip
To see the description of an action, hover over the
Action
field.
The description of the action appears in the tooltip:
Memory bank
selects the memory bank (
RFU
/
EPC
/
TID
/
User
)
Save select filter
data to file
saves the select filter data to file
Load select filter
data to file
loads the select filter data from file
On
activates or deactivates the select filter
Bit pointer
sets from which memory address the filter compares the mask data
Mask length
sets the mask length (0–255)