In the same menu, the basic functions of the GPIO card can be set.
First, the IO-card conguration is opened and the GPIO card set automatic detection on GPIO:
Here the global settings for the GPIOs are set.
Invertieren: when logically high level and high-level physica must be inverted
Debounce time depending on the switching element at the entrance
Output ->TAG found „antenna mistake“ ....
All these settings are global and apply to all congurations.
The Reader‘s launch SW sets in the folder „My Documents“ or in the user‘s „Documents \ Kathrein Sachsen GmbH“ to
a directory where the system variables are stored. Here are inter alia the antenna list and the Action List for the inputs.
The approximately 150 reader commands with corresponding variance of the parameters do not allow for uniform list.
A selection of all options is extensive. Therefore it is recommended to only list required in the application instructions.
To the Action List (ActionlistAction.xml) can use an XML editor to edit.
<?xml version=‘1.0‘ encoding=‘UTF-8‘?>
<ActionlistActions>
<!--Activate buzzer for 500 ms, CommandID: 0x0045, Parameter: 0x01F4-->
<Action>
<Description>Activate buzzer (500 ms)</Description>
<CommandID>0045</CommandID>
<!--LSB rst-->
<Parameter>F4</Parameter>
<Parameter>01</Parameter>
</Action>
<!--Get EPCs, CommandID: 0x0101-->
<Action>
<Description>Get EPCs</Description>
<CommandID>0101</CommandID>
<!--LSB rst-->
</Action>
</ActionlistActions>
In this example, the commands „Buzzer“ and were „Get EPCs“ registered.
The CommandIds can be found in the Reader Protocol ((A)).
After editing, the action list it in the reader startup directory under
„My Documents“ folder. The next time the reader start this software is active.
6.5.1.3. Setting up a separate list ACTION
6.5.1. Example of GPIO function