6. Operating the reader
6.10.9. Tag – User Group relationship
Finally, the unique transponders are assigned to the respective representatives of the user group, so as to achieve an
unambiguous classication and identication of vehicles and users.
This can be either a “Name”, “Username” or “ID”.
After expanding the input mask using the “>” button, the current transponder is read. This can always be re-launched
via the menu item “Update”.
With “Accept the selected tag” the EPC and TID of the selected transponder is transferred to the mask.
At the end the tab “Tag-user Group relationship” is used to assign the user to his user group.
Thus authorisations and the unique identier are dened by the transponder.
Since the processing of the Access Manager runs immediately into a SQL database on the Linux part of the reader,
the transponder is also connected immediately. It is recorded in the corresponding driveways, after the triggering of the
trigger and depending on its corresponding privileges, the barrier is opened or access is denied. Upon completion of
processing, the Ethernet cable can be removed. The application runs autonomously on the Linux part of the Kathrein
UHF RFID ETL / ELC Reader
6.11. Ethernet password
Secure Shell (SSH):
A secure shell connection can be established at the folder „Communication”. For this, the option “Secure connection”
has to be selected.