6. Operating the reader
Each input channel has two conguration parameters available. The Invert logical input option negates the electrical
input signal and uses this status for processing in the reader. If the check is not set, the signal is used unchanged.
Depending on the sensor being used (mechanical or electrical switch), a debounce time in milliseconds can be assigned
to each channel.
The outputs from the card can be assigned various functions. Further parameters can be activated, depending on the
function selected. The following functions are available:
1 Off – the selected output is deactivated
2 On – the selected output is always on
3 1Hz frequency – the selected output ashes at a frequency of 1 Hertz
4 2Hz frequency – the selected output ashes at a frequency of 2 Hertz
5 4Hz frequency – the selected output ashes at a frequency of 4 Hertz
6 8Hz frequency – the selected output ashes at a frequency of 8 Hertz
7 RF on – the output is active for Turn-off time milliseconds as soon as the radio frequency is present at the antenna
First antenna to Last antenna.
8 Antenna error – the output is active for Turn-off time milliseconds as soon as an antenna error occurs at antenna
First antenna to Last antenna.
9 Tag found – the output is active for Turn-off time milliseconds as soon as a tag is found at the antenna
First antenna to Last antenna.
10 RF on – the output is active for Turn-off time milliseconds as soon as an operation on a tag was successful at the
antenna First antenna to Last antenna.
11 Protocol access – the output is released and can be activated with all KBRP commands for GPIO.
Note
If the output is not set to protocol access, it cannot be accessed when processing action lists. See the
GPIO functions section for more details on action lists.
Once all the settings have been performed, the changes are loaded to the reader by pressing the Save changes
button, and take effect immediately.
Default conguration
No default conguration is provided for this card.
Note
If this card setting is changed from Auto detect or Card not used to GPIO, the reader must be restarted so that the
card is correctly initialised.