User's Guide

110 of 146
Operating the Reader Using the ReaderStart Software
<!--Get EPCs, CommandID: 0x0101-->
<Action>
<Description>Get EPCs</Description>
<CommandID>0101</CommandID>
<!--LSB first-->
</Action>
</ActionlistActions>
The example above shows the
Activate buzzer 500 ms
and
Get EPCs
actions.
16.7 Expert Settings 1
The ReaderStart software is a powerful tool for the reader conguration. It allows the reader to be customised to any
application. The
Expert settings 1
and
2
allow the reader's RF interface and communications prole to be optimised to
the tag so that the reader is optimally customised to the application.
There are eight parameter sets available for saving the reader conguration. It is possible to save all settings for the
transmission power, the antenna multiplex conguration, the RF settings and the air interface parameters.
Other parameters can be changed in
Expert settings 2
.
For more information about the individual parameters, refer to
Reader Conguration Manual for Kathrein RFID UHF
Readers
.
2 3
1
4
5
6 7 8 9 10 11
12
13
14
15
16
17
18
19
20
Fig. 67: Expert settings 1
Parameter Set
selects a parameter set
Get
reads the current settings of the selected parameter set in the system
Set
sets the parameters
Enabled
activates/deactivates the possibility to make changes in the port
Power
changes the power on the port (ERP)
dBm/W
switches between
dBm
and
W
ERP/EIRP
switches between
ERP
and
EIRP
Cable
attenuation
selects cable attenuation in the range between 0 and 63.75 dB