User's Guide

118 of 146
Operating the Reader Using the ReaderStart Software
16.9.4 Read Data
This group supplies detailed access to all the data areas of the tag. Access is obtained by entering the selected memory
bank, the address within the memory bank and the number of words.
2
4
6
7
8
9
3
4
1
5
Fig. 73: TestGen2: read data
Memory bank
enters the selected memory bank
Memory
address
enters the address within the memory bank
Word count
enters the number of words to read
Data (UTF8)
shows the data in the UTF8 format
Data (ISO
17367)
shows the data in the ISO 17367 format
Read data of
selected tag
reads data from the selected tag
Read com-
plete memory
bank of
selected tag
reads the complete memory bank of the selected tag; up to 255 words
Read data of
all tags
reads data from all tags in the eld
If the tags in the eld have dierent passwords and are congured dierently, it is nec-
essary to read the data from each tag individually.
Read com-
plete memory
bank of all
tags
reads the complete memory bank of all tags in the eld; up to 255 words