User's Guide

95 of 146
Settings
changes setting of the selected application
number of the expected tags
selects the antenna to be used
Check Ports 1-4 to select the antenna port. It is possible to select one, several or all
ports.
selects the parameter set in which the conguration is saved
sets the values for max. reading speed or max. reading reliability
Click
Optimised for reading speed
or
Optimised for reading reliability
.
The values in
Settings of selected application
( in
Fig. 50
) change.
When the max. read frequency is set (
Optimised for reading speed
is activated), the
number of readings is maximised. In this case, the same tag can be read several times,
because all tags will be reset in the inventory so that they will respond again. Because of
reading the same tag multiple times, in a scenario of moving tags it could happen that not
all the tags crossing the antenna eld are read. The frequency of detection of the same tag
is increased. In some cases, the time allowed for detecting the tags may be insucient, so
that some transponders are not detected.
When the max. read reliability is set (
Optimised for reading reliability
is activated), tags
that have already been read are not read again in the next inventory, provided they are still
being supplied with power. This means that only the tags which have not yet been regis-
tered are detected. This way, the probability that all tags are read is increased.
saves the settings that have been made as the settings for the selected application in the
selected parameter set. The programme resets the settings to the factory settings rst,
thus overwriting the previous conguration.
If the settings have been reset, the
Apply settings
button briey glows green and a suc-
cess message is displayed in the
Status
eld of the programme interface.
If case of a fault, the
Apply settings
button briey glows orange to indicate a warning or
red to indicate an error. If the fault has been caused by a missing entry, the eld lacking
the entry also glows red. A warning/error description is displayed in the
Status
eld.
After the settings have been loaded, it is possible to go to the
Basic reading
tab and to
start the read process.
Settings of
selected
application
shows the settings that have been made for the selected application in the selected parameter
set
Properties
of selected
application
shows the properties of the selected application
Tip
The read rate is inuenced by many parameters. In addition to the selected broadcasting prole with the
respective data rates, there are also application-specic data, e.g. how many tags the reader should expect
in the eld. You can optimise these parameters using the
Expert settings 1
and
2
.
If you are unsure whether the settings you have chosen are best suited for your application, contact
KATHREIN Solutions support at https://www.kathrein-solutions.com/support.