Tip
► If you would like to assign the action list to both the rising and the falling edge, click
Assign to rising
edge
and then
Assign to falling edge
.
To cancel the assignment:
► Restart/reset the reader or select
No action list
under
Action list
(⑧).
Adding Actions to the Programme
The action lists consist of a sequence of individual actions which can be loaded in the form of an XML le in the
Action
context menu:
2
1
Fig. 66: GPIO: action list, action context menu
①
Open le
"ActionlistAc-
tions.xml"
opens the actions list in the XML format in a text editor
②
Reload le
"ActionlistAc-
tions.xml"
reloads the action list; it is necessary to reload the action list after a new action has been added
to the XML le containing the actions or some changes have been made in it
The ReaderStart creates a directory in which the system variables are stored in the folder %userprofile%\Documents\
KATHREIN Solutions GmbH\ReaderStart v3. It is possible to edit the ActionlistActions.xml le manually using a text
editor.
► To see the individual actions, refer to the
Conguration Protocol
.
The approximately 150 reader commands with corresponding variance of the parameters do not allow for a uniform list.
A selection of all options is extensive. Therefore, it is recommended to only list commands required in the application.
The following example demonstrates the syntax of the actions:
<ActionlistActions>
<!--Activate buzzer for 500 ms, CommandID: 0x0045, Parameter: 0x01F4-->
<Action>
<Description>Activate buzzer (500 ms)</Description>
<CommandID>0045</CommandID>
<!--LSB first-->
<Parameter>F4</Parameter>
<Parameter>01</Parameter>
</Action>