5.6 Configure the Input Power
The downlink input power of the C-hub is as follows:
Nominal: 0 dBm
Maximum: 15 dBm.
Therefore, before accessing the RF signals, the signal power must be estimated. The
downlink input power must be monitored with a spectrum analyser or read the downlink
input power value from the combiners on the web GUI in order to set the downlink input
power within the appropriate range.
1. Open the master C-hubs web GUI as described under 4.3, p. 15/4.4, p. 24.
2. Go to Settings Combiners.
3. Set the attenuation control mode to Manual or Auto
1)
(①ⓐ in Fig. 12).
4. Scroll to display the parameters of a C-hub channel to be congured; see Fig. 12
showing the example of Channel1.
5. Check the channel's band frequency .
6. Check the channel's input power per port .