8.2.6 Settings > Combiners
Parameter Description
Type
General
Combiner att control mode Manual: The attenuation of the input
power must be set manually
using the parameters Port x
attenuation value below.
Auto: The attenuation is set
automatically.
W
Adjust interval Period of the input power level being below
0 dB, after which the attenuation will be raised
(6/12/24 hours).
1)
24 hours is recommended.
W
Channel 1
Power switch W
UL freq low R
UL freq high R
DL freq low R
DL freq high R
Port x input-power value Input power level R
Port x attenuation value Attenuates the input-power to achieve Port x
input-power value to be 0 dBm.
W
Port x power offset Additional attenuation in case of rising
composite power due to multiple carriers input.
W
Port x operator Operator information, e.g. name
W
Channel 2 ... 4 See Channel 1
Tab. 5: Combiner parameters C-hub
1)
Example: The input power is less than maximum during a period of 24 hours, then the attenu-
ation decreases (2 dB).
2)
Example: A power offset of 3 dB is recommended if an input of 2 carriers exists.