User's Manual
Table Of Contents
- 1 About this Document
- 2 General Information
- 3 Preconditions and Requirements
- 4 Installing the C-Hub
- 5 Installing the E-Hub
- 6 Installing the HPRU
- 7 Cabling
- 8 System Documentation
- 9 Glossary
- 10 List of Diagrams
- 11 List of Tables
- Fig. 1: Scope of delivery
- Fig. 2: Example of a handover point for the BTS signals at a c-rail
- Fig. 3: Example of a handover point for the BTS signals with individual loads with short patch cables at a c-rail
- Fig. 4: Clearance Ⓐ above radiation fins of the installed devices
- Fig. 5: Sliding rails Ⓑ
- Fig. 6: Power distribution bar ① mounted on the left-hand traverse
- Fig. 7: Plugs for power connection: ① is for red circuit, ② for black circuit
- Fig. 8: Attaching a 19" mounting bracket
- Fig. 9: Attached sliding rails Ⓑ
- Fig. 10: Place C-hub in rack
- Fig. 11: Fix C-hub with screws
- Fig. 12: Connect power cable at rear side
- Fig. 13: Connect ground cable at rear side
- Fig. 14: Attaching a 19" mounting bracket
- Fig. 15: Marking position of mounting holes
- Fig. 16: Mounting completed
- Fig. 17: Connect power cable at rear side
- Fig. 18: Connect ground cable at rear side
- Fig. 19: Attaching handle
- Fig. 20: Attaching bracket Ⓐ
- Fig. 21: Marking mounting holes for bracket Ⓑ
- Fig. 22: Prepare expansion bolts for bracket Ⓑ
- Fig. 23: Mounting accessories for bracket Ⓑ
- Fig. 24: Bracket Ⓑ mounted
- Fig. 25: Hook HPRU into bracket Ⓑ (①) and fix from top (②).
- Fig. 26: HPRU fixed from top
- Fig. 27: Fix HPRU from side
- Fig. 28: Connect power cable at bottom side
- Fig. 29: Connect ground cable at bottom side
- Fig. 30: Interfaces at the C-hub front side
- Fig. 31: Interfaces at the C-hub rear side
- Fig. 32: Interfaces at the E-hub front side
- Fig. 33: Interfaces at the E-hub rear side
- Fig. 34: Interfaces at the HPRU connector side
- Fig. 35: Fibre optical cable layout
- Fig. 36: Coaxial cable layout
- Fig. 37: Power supply cable layout
- Tab. 1: Symbols and signal words
- Tab. 2: Storage of the system documentation
40 of 64
Structure of the Web GUI
936.5468 0.92
8.2.7 Settings > LAN Connectivity
Parameter Description
Type
General
Vendor name Name of the company running the system; the
name is xed in the device's rmware
R
Product model Product name; xed in the device's rmware R
Serial number Serial number of the device R
Software edition Edition of the software running on the device R
FPGA edition Edition of the rmware running on the device R
Device ID Customer specic device ID W
Device sub ID Customer specic device sub-ID W
Device location Installation location of the device W
Site ID Site ID W
IP settings
Protocol select W
NMS IP addr W
NMS port W
Trap IP addr1 Destination IP address used for SNMP traps W
Trap IP addr2 ditto W
Trap port Destination IP port used for SNMP traps W
Device ID addr IP address of the master C-hub W
Subnet mask Subnet mask of the master C-hub W
Default gateway Default gateway of the master C-hub W
Device port (UDP) Device port of the master C-hub W
Heartbeat interval time W
Date and time
Date and time Date and time of the C-hub's internal clock W
Site report
Site report B
Slave local network
Slave local network W
Tab. 6: LAN connectivity parameters C-hub