53 of 64936.5468 0.92
8.4.7 Alarms > Alarm
Parameter Description
Type
Alarm
Power interruption alarm See description under 8.2.8, p. 41.
MOV alarm ditto
Open case alarm ditto
Overtemperature alarm ditto
LO x unlocked alarm ditto
CH x UL ALC out-of-ctrl alarm
CH x VSWR alarm
OP slave transceiver-failure alarm
OP master transceiver-failure alarm
CH x DL under-output-power
alarm
CH x DL over-output-power alarm
Link alarm
Tab. 23: Alarm parameters HPRU
8.4.8 Alarms > Alarm Thresholds
Parameter Description
Type
Alarm thresholds
CH x DL under-output-power
threshold
Output-power threshold below which an alarm is
triggered.
W
CH x over-output-power threshold Output-power threshold above which an alarm
is triggered.
W
VSWR threshold VSWR threshold above which an alarm is
triggered.
1)
Overtemperature threshold See description under 8.2.10, p. 42. W
Tab. 24: Alarm threshold parameters HPRU
1)
Typically, the value is set to 2.5.