Type MSK 200/S2 MSK 200/M4 MSK 200/ME MSK 200/MT
Part no. 21710024 (75 Ω)
21710025 (50 Ω)
21710026 (75 Ω)
21710027 (50 Ω)
21710034 (75 Ω)
21710035 (50 Ω)
21710042 (75 Ω)
21710043 (50 Ω)
Spectrum analyser
Frequency range MHz 5-3100
Resolution bandwidth (-3 dB) kHz
MHz
1, 3, 10, 30, 100, 300
1, 3
Resolution bandwidth (-6 dB) kHz 9, 25, 50, 120, 200
Video bandwidths MHz 0.00001-3
Phase noise at 10-kHz carrier spacing dBc < -90 (1 Hz), typ. -95 (1 Hz)
Phase noise at 100-kHz carrier spacing dBc <-100 (1 dB), typ. -110 (1 Hz)
Dynamic (RBW: 100 kHz) dB Type 70
Level measuring range dBμV 30-130 / -128 (50 Ohm)
Total input power max. W 0.5
Measurement accuracy dB < 1.5
Measurement detector dB Max peak, min peak, auto peak, sample, RMS
Return loss (5-dB pre-attenuation) dB > 16 (VSWR: 1.35)
Refresh rate Pic./s Max. 10
Reference level dBμV 30-130
Display range dB 100, 70, 50, 30, 20, 10
Screen resolution Pixels Max. 800 x 600/nominal 501 x 401
FM radio receiver
Frequency range MHz 87.5-108
Channel bandwidth kHz 300
De-emphasis μs 50/75
Analogue TV receiver
Frequency range MHz 10-895
Standards B/G, I, D/K, L/L´, M/N
Colour standards PAL, SECAM, NTSC
Audio standards IRT-A2, NICAM, BTSC, EIA-J
Nicam bit error rate 1.0E-9...1.5E-2
Channel bandwidth MHz 6/7/8
Frequency increment kHz 50
Video IF bandwidth According to standard
Audio IF bandwidth According to standard
Audio de-emphasis μs 50/75
Video output voltage/impedance Vpp/Ohm 1/75 ± 1 dB
Hum measurement (suppression) dB > 50
S/N measurement (evaluated according to
CCIR Rec. 567)
dB > 55/typ. 57