User manual

3 / 13
Setting up
Mounting
1. Choose the mounting location with regard to the minimum clearances to avoid a build-up of heat; see Abb. 1.
2. Mount the screws with d
max
= 4 mm and do not do them up tightly; see Abb. 2 and the attached drilling template.
3. Install the equipotential bonding in accordance with the regulations (cable shoe).
4. Suspend the UFO 30 and do the screws up tightly.
5. If required, t F-type connectors to the HF connecting cables; see Abb. 3.
6. Connect the HF connecting cables in accordance with the system planning.
Fig. 1: Clearances to containing surfaces Fig. 2: Dimensions and installation dimensions
Max. 2 mm protrusion
Tightening torque
3.4 Nm max. (risk of
overtightening)
Diameter 0.6 – 1.2 mm
1)
free of burrs
Fig. 3: Attachment of the F-type connector
1)
If the cable inner conductor diameter is greater than 1.2 mm, or in the case of burrs, the device sockets may be damaged beyond
repair.