Operation Manual

935.2155/D/0705/4.4e/SKS Technical data subject to change!
6. Selecting the position of the output spectrum
7. Aligning the channel unit
Inp. 2004 MHz
22,000 MS/s 5/6
Outp. S21 306,00 MHz
6,111 MS/s 64 QAM
After having selected the parameter „… QAM“, press
and go to the sub-menu.
The output level of the channel unit can be adjusted
with the aid of the level adjuster (on front panel). Recom-
mended level range on output of the reception system
UFG 308/312/316: 75…90 dBµV / 75 .
Level measurement requires the use of a QAM capable
signal meter (e. g. MSK 33 from Kathrein).
The measuring instruments from Kathrein mentioned in
the following can also be used, provided that the
corresponding correction values are added to the
displayed value.
Signal meter Measuring Correction value
Type function (for 64 QAM; 6,875 MS/s)
MFK 50 F5 + 0,5 dB
MFK 55 F94 + 0,5 dB
MFK 85
MSK 31 + 2 dB
Select the parameter „Spectrum“ in the sub-menu with
“ or „“.
Select the operation mode „normal/inverse” with
„+“ or „-“.
**** UFO385 * * * *
Modulation SAT-Signal
Spectrum normal
< Back to: sub-menu >
KATHREIN-Werke KG · Anton-Kathrein-Straße 1–3 · P.O. Box 10 04 44 · 83004 Rosenheim · Germany · Tel. +49 (0) 80 31 18 40 · Fax: +49 (0) 80 31 18 43 06
UFO 387 UFO 387
UFO 387
VHF, UHF
VHF
VHF
VHF
UFO 385
Remote power
supply
Control unit