Service Manual

ELECTRICAL SYSTEM 16-29
Battery
Terminal Voltage: 11.5 less than 12.6 V
Standard C harge
1.8 A × 5 10 h
(see following chart)
Quick Charge
9.0 A × 1.0 h
CAUTION
If possible, do not quick charge. If quick charge is
done unavoidably, do standard charge later on.
Terminal Voltage: less than 11.5 V
Charging Method:
1.8 A × 20 h
NOTE
Increase the charging voltage to a maximum voltage of
25 V if the battery will not accept current initially. Charge
for no more than 5 minutes at the increased voltage then
check i f the battery is drawing current. If the battery
will accept current decrease t he voltage and charge by
the standard charging method described on the battery
case. If the battery will not accept current after 5 min-
utes, replace the battery.
Battery [A]
Battery Charger [B]
Standard Value [C]
Adjust voltage so that the current will be standard value
after 5 minutes [D].
Determine t he battery condition after refresh charge.
Determine the condition of the battery left for 30 minutes
after com pletion of the charge by measuring the terminal
voltage according to the table below.
Criteria
Judgement
12.6 V or higher Good
12.0 lowerthan12.6V
Charge insufficient Recharge
lower than 12.0 V Unserviceable Replace