User's Manual

16-70 ELECTRICAL SYSTEM
Meter, Gauge, Indicator Unit
Fuel Level Gauge Inspection:
Connect t he 12 V battery and terminals in t he same man-
ner as specified in the “Liquid Crystal Display (LCD) Seg-
ments Check”.
Connect a variable rheostat [A] to terminal [4] and [9] as
shown.
Check that the number of segment [B] matches the resis-
tance value of the variable rheostat.
Resistance () Number of Segments
0 16.5 F6
11.5 34.5 5
26.5 52.5 4
41.5 70.5 3
56.5 88.5 2
71.5 above E1
If this display function does not work, replace the meter
assembly.
Connect an other variable rheostat [C] to terminal [2] and
[9] as shown.
Set the hand tester [D] to the DC 10 V range and connect
it to terminals of the variable rheostat as shown.
When the 1 segment [E] appears, adjust the variable
rheostat [C] so that the terminal voltage is less than 5.7 V.
Then the 1 and FUEL segments should flush.
If this display function does not flush, replace t he meter
assembly.
Tachometer Check:
Connect t he 12 V battery and terminals in t he same man-
ner as specified in the "Liquid Crystal Display (LCD) Seg-
ments Check".
The revolutions per minute (rpm) equivalent to the input
frequency is indicated in the oscillator [A] if the square
wave (illustrated as shown) would be input into the termi-
nal [7].
Indicates approximately 6000 rpm in case the input fre-
quency would be approximately 200 H z.