User's Manual

Table Of Contents
Chapter 11: Qualification Reports
Kaye ValProbe RT User Manual 103
11.3. Qualification Summary Report
Summary Reports are created from raw encrypted Qualification files and as titled, for each
Group provide a summary by cycle of all sensor measurements during the Qualification study.
All calculations performed by the Summary report are set by the Storage rate as defined in the
Setup. The main report header provides the same traceability information for the study as
defined in the Detailed report.
The remaining sections of the Summary cover pages include the same information as defined
in the Detail Report.
The body of the report is arranged by groups. For each group, the Summary report contains
two sections, Temperature data tables and Temperature Summary data tables.
The Temperature Data Table include a listing of each sensor in the Group, the Min, Max, Avg,
Lethality, and Max-Min values for each cycle defined in the study (i.e. Heat up, Exposure,
Cooldown).
Temperature Summary data tables include at the bottom of the page, a data summary for
each cycle for all sensors in the group. Table calculations include:
Cycle start time and date
Cycle duration
Min of Min, Sensor ID, date and time
of occurrence
Max of Max, Sensor ID, date and
time of occurrence
Max range
Max spread and time of occurrence
Min and Max accumulated Lethality
and from which sensor
Avg of Avg
Max of all (Max - Min) for all sensors
contained in the group.
Once groups are documented, the last pages of the report list System and Event messages
and the Footer as defined in the report options.
Prior to printing the Summary report, inside the Report content options, you can add Setup
information and a graph of the complete study to the Summary report.
Figure 117: Summary Report