User's Manual
Table Of Contents
- Appendix B. Regulatory Compliance and Agency Approvals
- Chapter 1. Kaye ValProbe RT System
- Chapter 2. Kaye ValProbe RT Hardware
- Chapter 3. ValProbe RT System Connections
- Chapter 4. Creating User Accounts
- Chapter 5. Defining Equipment
- Chapter 6. Defining Assets
- Chapter 7. Defining Study Setups
- Chapter 8. Viewing Live Data
- Chapter 9. Qualification Study
- Chapter 10. Sensor Verification
- Chapter 11. Qualification Reports
- Appendix A. Specifications
- A.1 Kaye ValProbe RT System
- A.1.1 List of Certified Countries
- A.1.2 Regulatory Compliance
- A.1.3 RF System Operating Frequency and Modulation
- A.1.4 RF Channels
- A.1.5 RF Network Topology and PAN ID (Network ID)
- A.1.6 Antenna Diversity
- A.1.7 Data Rate and Data Encryption
- A.1.8 RF Range (Line of Sight and Outdoor)
- A.1.9 Number of Loggers and Sensors Supported
- A.1.10 Sensor Sampling Rate
- A.1.11 Data Transmission Rate
- A.1.12 Sensor Samples Data Storage Capacity
- A.1.13 Optional Extendable Base Station Antenna
- A.2 Kaye ValProbe RT Base Station
- A.2.1 Input Power and Adaptor Ratings
- A.2.2 Installation Category
- A.2.3 Overvoltage Category and Electrical Safety Protection Class
- A.2.4 Input DC Power On/Off Switch
- A.2.5 Front Panel LED Indications and Buzzer
- A.2.6 Bath and IRTD Interface Ports
- A.2.7 USB Port
- A.2.8 Ethernet Communication Port
- A.2.9 Reset Switch to Reload Default Factory Settings
- A.2.10 Wakeup Magnet
- A.2.11 Batteries
- A.2.12 Unit Dimensions
- A.2.13 Enclosure Material
- A.2.14 Environmental Ratings
- A.3 Kaye ValProbe RT Logger
- A.3.1 Installation Category
- A.3.2 Overvoltage Category and Electrical Safety Protection Class
- A.3.3 Magnetic Switch
- A.3.4 LED Indications
- A.3.5 Calibration
- A.3.6 Real Time Clock Accuracy
- A.3.7 Sensing Elements
- A.3.8 Housing Material
- A.3.9 Logger Base Dimensions
- A.3.10 Ingress Protection
- A.3.11 Insulating Canister X2545
- A.3.12 Battery
- A.3.13 Shelf Life
- A.3.14 Battery Life
- A.4.1 Measurement Accuracy
- A.4.2 Body Environmental Ratings:
- A.4.3 Number of Input Channels
- A.4.4 Sensor Types and Measurement Range
- A.4.5 Sensor Lengths
- A.5.1 Measurement Accuracy
- A.5.2 Body Environmental ratings:
- A.5.3 Number of Input Channels
- A.5.4 Sensor Types and Measurement Range
- A.5.5 Sensor Lengths
- A.6.1 Measurement Accuracy
- A.1 Kaye ValProbe RT System
- Appendix B. Regulatory Compliance and Agency Approvals
- B.1 Electrical Safety Approvals:
- B.2 Radio and EMC Certification Approvals:
- B.3 Ingress Protection for Kaye ValProbe RT Logger
- B.4 United States FDA 21 CFR Part 11 Complaint Software Application
- B.5 Transportation Regulations
- B.6 FCC Compliance Statement
- B.7 ISED Canada Compliance Statement
- B.8 EU Compliance Statement:
- B.9
- Product Certification Labels
- Appendix C. Environnemental Compliance
- Appendix D. Warranty and Returns:
- Appendix E. Service Information
Appendix B. Regulatory Compliance and Agency Approvals
Kaye ValProbe RT User Manual 142
B.2.2 European Radio and EMC Certification Approvals:
Kaye ValProbe RT is certified to Europe Radio and EMC standards listed
below:
ETSI EN 300 328 V2.1.1:2016-11 Wideband transmission systems; Data
transmission equipment operating in the 2,4 GHz ISM band and using wide
band modulation techniques - RED (2014/53/EU).
ETSI EN 301 489-1 V2.2.0:2017-03 Electromagnetic Compatibility (EMC)
standard for radio equipment and services; Part 1: Common technical
requirements - RED (2014/53/EU).
ETSI EN 301 489-17 V3.2.0:2017-03 Electromagnetic Compatibility (EMC)
standard for radio equipment and services; Part 17: Specific conditions for
Broadband Data Transmission Systems - RED (2014/53/EU).
EN 62311:2008 Assessment of electronic and electrical equipment related to
human exposure restrictions for electromagnetic fields (0 Hz - 300 GHz) -
RED (2014/53/EU) and LVD (2014/35/EU).
EN 61326-1:2013 EMC requirements for Electrical equipment for
measurement, control and laboratory use; Part 1: General requirements –
EMC directive 2014/30/EU.
IEC 61326-1:2012 EMC requirements for Electrical equipment for
measurement, control and laboratory use; Part 1: General requirements -
ISO/IEC Directives, Part 2.
B.3 Ingress Protection for Kaye ValProbe RT Logger
Kaye ValProbe RT Logger is certified to EN60259 / IP68 Ingress Protection standard.
IP68 Ingress Protection (IP code): Degrees of protection provided by enclosures as
per EN 60529:1991+A1:2000+A2:2013 standard.
IP6X: Protection against access to hazardous and solid foreign objects and dust proof
test.
IPX8: Protection against continuous immersion in water test.
B.4 United States FDA 21 CFR Part 11 Complaint Software
Application
Kaye ValProbe RT product software application is complaint to US FDA 21 CFR
Part 11 regulatory standard for electronic records and electronic signatures.
US FDA 21 CFR Part11; United States Food and Drug Administration,
Department of Health and Human Services – General Provisions; Electronic
Records; Electronic Signatures.