Cut Sheet

DATA SHEET D-220
KBCC
Chassis Mount Variable Speed DC Motor Control
for Shunt Wound and PM Motors thru 3 Hp
Patented Overload Circuit
TYPICAL APPLICATIONS
Transfer Pumps • Door Openers • Feeders
• Indexers • Tapping Machines • Conveyors
• Robotics • Screen Presses
• Exercise Equipment
STANDARD FEATURES – All Models
PLUG-IN HORSEPOWER RESISTOR
®
CHART
Tachometer or Armature Feedback
Plug-in Horsepower Resistor
®
Built-in AC Line and Armature
Fuses
MOV Transient Protection
Trimpots: MIN, MAX, IR, CL, ACCEL, DECEL
Rugged Aluminum Heatsink
Voltage Following
Auto Inhibit
®
, Inhibit™ and Enable
CL LED Indicator
Forward-Brake-Reverse
Anti-plug Instant Reverse
Run-Brake-Jog
Auxiliary Trimpot for Speed Adjustment
Rapid Cycling
Armature Fuse and Plug-in Horsepower
®
are supplied separately.
A Complete Line of Motor Drives
Rev.______(A_______)
TM
DESCRIPTION
The KBCC chassis control utilizes the KBMM™ modular
control to provide a low-cost, reliable, variable speed SCR
drive for PM and Shunt Wound DC motors. Models with
the “R” suffix contain the KB APRM
®
* which provides
anti-plug “instant” reverse and solid state dynamic
braking. All models are equipped with KB’s exclusive
Plug-in Horsepower Resistor
®
. It eliminates the need for
recalibrating IR Comp and Current Limit when the control
is used on various horsepower motors. The controls also
contain Inhibit™ which allows for electronic switching of
the armature voltage and Auto Inhibit
®
which provides
rapid safe switching of the AC line.
The KBCC controls are built on a rugged aluminum
heatsink and contain AC line and armature fusing, a 5K
ohm remote potentiometer, and a barrier terminal block.
In lieu of the potentiometer, the control can be operated in
a voltage following mode by supplying an
isolated
analog
signal (0-9VDC) to the input terminals P2 (+) and F-.
Adjustment trimpots are provided for MIN, MAX, IR COMP,
CL, ACCEL and DECEL.
* Patented.
SPECIAL FUNCTIONS – “R” Suffix Only
SPECIFICATIONS
TM
Speed Range (Ratio) ...................................................... 50:1
Load Regulation
(0 – Full Load, 50:1 Speed Range)(% Base Speed) ...... 1*
Line Voltage Regulation
(At Full Load, ± 15% Line Variation) (% Base Speed).... 1/2*
Control Linearity
(% Speed vs. Dial Rotation).............................................. 2
CL Torque Range
(% Full Load) .......................................................... 0 – 200
ACCEL/DECEL Time Range (Secs.) .......................... .2 – 10
MIN Speed Trimpot Range
(% Full Speed) ........................................................ 0 – 30*
MAX Speed Trimpot Range
(% Full Speed) .................................................... 50 – 120*
Maximum Allowable Ambient Temperature
(At Full Rating °C/°F) .............................................. 45/113
Maximum Number of Starts/Stops or Reversals
(Operations/Minute).......................................................... 30**
Motor Horsepower Range
Armature Voltage
90 – 130 VDC
Armature Voltage
180 VDC
Plug-in-Horsepower
Resistor
®
Resistance Value
(ohms)
1/100 – 1/50 1/50 – 1/25 1.0
1/50 – 1/30 1/25 – 1/15 .51
1/30 – 1/20 1/15 – 1/10 .35
1/20 – 1/12 1/10 – 1/6 .25
1/12 – 1/8 1/6 – 1/4 .18
1/8 – 1/5 1/4 – 1/3 .1
1/4 1/2 .05
1/3 3/4 .035
1/2 1 .025
3/4 1
1
2 .015
1 2 .01
1
1
2 3 .006
* Performance is for 90V PM motors on 115 VAC and 180V PM motors on 230 VAC.
** Based on a brake time of one (1) second. For increased operations per minute
and longer brake time, contact factory.
* CE Compliance Requires KBRF-200A RFI Filter
14
KBCC
Unidirectional
KBCC-R
Instant Reversing
Solid State Dynamic Braking
*
®

Summary of content (2 pages)