User guide

5. FWD-BRK-REV switch remote moun-
ted. It is possible to operate the con-
trol with a remote FWD-BRK-REV
switch or with a remote relay. Care-
fully remove the three switch wires:
S1, S2, S3 from the APRM
®
. Wires
may be extended for remote operation,
but it is suggested that a shielded
cable be used. (See table 1 APRM
®
Operation, p. 2.)
IV. WIRING. Do not wire control
with AC line connected.
1. Carefully remove from the KBPC main
PC board the 2 jumpers, J8A (con-
nects A1A and A1B) and J8B (con-
nects A2A and A2B). Note: Use long
nose pliers and rock terminal back
and forth to facilitate removal. (See
fig. 2.)
2. Install the wires from the APRM onto
the following terminals on the KBPC
main board. Refer to the internal wiring
diagram provided. (See fig. 5, p. 6.)
FIG. 2 KBPC-240D JUMPER REMOVAL
4