FIGURE 12. INTERNAL SENSING
Internal Sensing Circuit -
Wire the KBAP® in accordance with this wiring diagram.
9.6 Optional Overload Protection with KBAP-240D (Part No. 9106)
The KBAP-240D
®
is a multipurpose DC
Current Sensing Relay and Overload
Protector. It is specifically designed for use
with DC motors and speed controls from 1/8
- 3 HP. KBAP-240D
®
operates by sensing
current in the armature circuit. When the
preset level is reached, the output relay
(RY1) trips. An adjustable time delay (0.2 -
15 secs.) is incorporated, which eliminates
nuisance tripping. Manual or automatic reset
is provided at the user's option along with a
LED, which indicates when the preset
current level has been reached. When an
overload occurs, the KBAP-240D
®
can be
used to shut the system down, sound an
alarm, or initiate corrective action before
damage occurs. Refer to Figure 12.
10 OPTIONAL ACCESSORIES
Auxiliary Heat Sink (Part No. 9861): Doubles the horsepower rating of the control.
Barrier Terminal Accessory Kit (Part No. 9863): When used with the Auxiliary Heat Sink, it converts the
quick-connect terminals of the control to a barrier terminal block.
Barrier Terminal Board (Part No. 9884): Converts the quick-connect terminals of the control to a barrier
terminal block. Contains PC board mounted line and armature fuse holders (fuses supplied separately).
Plugs onto the quick-connect terminals of the control.
SI-5 Signal Isolator (Part No. 9443): Provides isolation between non-isolated signal sources and the
control. Plugs onto the quick-connect terminals of the control.
Dial Plate & Knob Kit (Part No. 9832): Provides indication of the Main Speed Potentiometer position
(0 – 100 %).
AC Line & Armature Fuse Kit (Part No. 9849): Provides fusing for the AC line input and armature.
Includes wired fuse holders and mounting screws. Fuses supplied separately.