User Manual

(jumper J3 set to “TCL” position). The control can be reset by either setting the start/stop
switch to “START” position or by disconnecting and reconnecting the AC line. If the over-
load condition still exists when the control is restarted or AC line reapplied, the OL LED
will illuminate again. If the OL LED remains illuminated during control operation, a fault
condition may exist. Possible causes for this condition are as follows:
Motor is overloaded. Check motor current. If the motor is a shunt wound type, the field
may be open or not receiving proper voltage.
Motor may be defective. Check motor for shorts or grounds.
CL may be set too low. Check position of CL trimpot and setting of jumper J2.
Note: In some applications, especially those requiring the motor to cycle on and
off, or from one speed to another, or from stop to high speeds, the OL LED may
blink, indicating a transient overload. This may be a normal condition for the appli-
cation.
X. OPTIONAL ACCESSORIES
Complete instructions and connection diagrams are supplied with all accessories to facilitate
installation.
A. On/Off AC Line Switch (P/N 9341) Disconnects the AC line. Mounts on the enclosure
cover and is supplied with a switch seal to maintain watertight integrity.
B. FWD-BRK-REV Switch (P/N 9339) Provides motor reversing and dynamic braking.
This switch is equipped with a center off hesitation mechanism, which assures that the
motor is fully stopped before it can be reversed. Mounts on the enclosure cover and is
supplied with a switch seal to maintain watertight integrity.
C. Run-Stop-Jog Switch (P/N 9340) Selects speed setting from either main potentiome-
ter or JOG trimpot. Mounts on the enclosure cover and is supplied with a switch seal to
maintain watertight integrity.
D. Signal Isolator KBSI-240D (P/N 9431) Provides isolation from non-isolated signal
sources. Mounts on the inside of the enclosure cover.
E. Auto/Manual Switch (P/N 9377) – When used with the KBSI-240D (P/N 9431), it selects
either an isolated signal from the KBSI-240D or from the main speed potentiometer.
Mounts on the enclosure cover and is supplied with a switch seal to maintain watertight
integrity.
F. Anti-Plug Reversing Module APRM-PC (P/N 9378A) – Provides electronic braking and
reversing. Mounts on the inside of the enclosure cover.
Note: For use with this control, the APRM-PC must be Revision A or newer.
G. KBRF-200A RFI Filter (P/N 9945C) Provides RFI and EMI suppression. Meets CE
directives.