User Guide

12
Note: Disconnect main power when installing or changing the Plug-In
Horsepower Resistor®.
III. WIRING INSTRUCTIONS
Warning!
Read Safety Warning, on page 5 before using this control.
Disconnect the AC line before wiring.
Note: To avoid erratic operation, do not bundle AC line and motor wires with wires
from signal following, Start/Stop Switch, Enable, or any other signal wires. Use
shielded cables on all signal wiring over 12 (30cm). Shield should be earth ground-
ed on the control side only. Wire the control in accordance with the National
Electrical Code requirements and other codes that may apply to your area. See
Figure 4 on page 13.
Be sure to properly fuse each conductor that is not at ground potential. Do not fuse
neutral or grounded conductors. See Section VIII, on page 18. A separate AC line
switch or contactor must be wired as a disconnect so that each ungrounded con-
ductor is opened. See Application Note, Section VII, on page 18.
0.18
SCR Rated Motor
Horsepower Ranges (HP)
PWM Rated Motor
Horsepower Ranges (HP)
Motor
Current
(Amps DC)
9836
3.3 5.0
Plug-In
Horsepower Resistor®
90 Volt DC 180 Volt DC 130 Volt DC 200 Volt DC Part No.
9949
1/3 1/2
1/4
0.1
0.25
0.51
1
2.0
9838
9837
9834
9833
3/4 1
1/100 1/50
1/2
1/15 1/10
1/8 1/6
1/30 1/20
1/4 1/3
1/6 1/5
1/15 1/10
1/50 1/25
1/2 3/4
1/3
1/6 1/4
1/12 1/8
1/20 1/15
1/50 1/30
1 1
1
2
3/4
1/3 1/2
1/6 1/4
1/8 1/6
1/25 1/20
2.5
1.3 2.0
0.7 1.0
0.4 0.6
0.1 0.3
TABLE 3 – PLUG-IN HORSEPOWER RESISTOR® SELECTION
Notes: 1) 1 HP = 0.75 kW. 2) The HP marking on the Plug-In Horsepower Resistor® does not apply to PWM controls.
!
CL Setting
(Amps DC)
0.5
7.5
3.8
3.0
1.5
0.9
!