User Guide
III. Connections to the SIMG
Safety Warning! Do not use FWD-STOP-REV contacts as a safety discon-
nect since they are not fail-safe. Use only the AC line for this purpose.
Note: SIMG Enable jumper J1 must be installed, or a connection must be made
between EN and COM terminals of SIMG TB1 in order for the KBMG to operate.
A. Voltage Following
– Uses a
voltage source to vary motor
speed. See figure 10. Connect
the voltage source to TB1 ter-
minals SIG and COM. When a
0V DC signal is applied, the
control will operate at the mini-
mum set speed (set by the
OFFSET trimpot on the SIMG).
When a 10V DC signal is
applied, the motor will operate
at the maximum set speed (set
by the MAX trimpot on the SIMG).
Applying a positive (+) signal to SIG terminal, with respect to COM terminal, will oper-
ate the motor in the forward direction.
12
!
3.5
Connection Designation
Supply Wire Gauge (AWG – Cu)
Maximum Tightening Torque
(in-lbs)
MaximumMinimum
Logic Connections 24 14
TABLE 2 – TERMINAL BLOCK (TB1) WIRING INFORMATION
(KBMG Jumper J4 in 10V Position)
(SIMG Enable Jumper J1 Installed)
± 10VDC
EN COM SIG -15 +15
J1
TB1
VDC
FIGURE 10 – VOLTAGE FOLLOWING
CONNECTION