Operating the KDS Legato 200 Series
KDS Legato 200 Series Users Manual
KD Scientific Legato 200 Series Syringe Pump Users Manual
Publication 5617-002-Rev F
Run Mode Errors
ERROR 101- Power to the pump was lost.
ERROR 102- The A/D convertor is not working.
Set-up Errors
ERROR 201- Backlight setting out of range, 10 to 100
ERROR 202- Alarm setting out of range, 1 to 99
ERROR 203- Force percentage out of range, 1 to 100.
ERROR 204- Pump address out of range, 0 to 99.
ERROR 205- Pump number out of range, 1 to 99.
ERROR 206- Syringe volume out of range, 0.05 µl to
1000 ml.
ERROR 207- Syringe diameter out of range, 0.1 mm to
99 mm.
ERROR 208- Date is out of range.
ERROR 209- Time is out of range.
ERROR 210- Infuse Rate out of range.
ERROR 211- Withdraw rate out of range.
ERROR 212- Syringe diameter is out of range.
ERROR 213- Target volume exceeds syringe volume.
ERROR 214- Target time exceeds syringe volume.
ERROR 215- Total volume exceeds syringe capacity.
ERROR 216- Volume is less than the minimum value.
ERROR 217- Motor has stalled.
ERROR 218- Program needs a rate.
ERROR 219- Program needs infuse and withdraw rates
and a target volume.
ERROR 220- Date/Time entered out of range.
ERROR 221- Incorrect Password.
P
rogram Errors
ERROR 301- Delay time out of range, must be at least
0.20 seconds.
ERROR 302- Number of steps must be between 2 and
500.
ERROR 306- Download to remote pump incomplete.
ERROR 307- Syringe size and flow rate not
compatible, cannot set motor speed.
ERROR 308- File exists.
E
RROR 309- Linked to program does not exist.
ERROR 310- Not all fields have been set.
ERROR 311- Rate is out of range.
ERROR 312- Time is out of range.
ERROR 313- Volume is out of range.
ERROR 314- First rate is out of range.
ERROR 315- Second rate is out of range.
ERROR 316- First time is out of range.
ERROR 317- Second time is out of range.
ERROR 318- First volume is out of range.
ERROR 319- Second volume is out of range.
ERROR 320- The pulse count is 0.
ERROR 321- Bad memory sector in step #%d. Step
was deleted.
ERROR 322- Volume exceeds syringe capacity
in step #%d.
ERROR 323- Incompatible rate vs. syringe size in step
#%d.
ERROR 324- Repeat count is 0.
ERROR 325- “Go To” cannot link to itself.
NOTE: Error and Alarm text are shown in a
yellow box whereas Notice, Confirm and
Verified are shown in a green box.
R
un Mode Errors: Error 1XX
Set-up Errors: Error 2XX
Program Errors: Error 3XX
Critical Errors: Error 4XX
ERROR CODES