INSTANT RECOVERY® GAS FRYER SERVICE MANUAL KEEP THIS MANUAL FOR TRAINING NEW PERSONNEL 1-800-KEATING www.keatingofchicago.
TABLE OF CONTENTS SECTION I INTRODUCTION Safety Precautions . . . . . . . . . . . . . . . . . . . . . . .1-2 SECTION II INSTALLATION Damage During Shipment . . . . . . . . . . . . . . . . . . .2 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Positioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3 Leveling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Restraining Devices . . . . . . . . . . . . . . . . . . . . . . .3 Gas Connection . . . . . . .
POST THIS LABEL IN A PROMINENT LOCATION ON YOUR UNIT IMPORTANT IN THE EVENT A GAS ODOR IS DETECTED, SHUT DOWN UNITS AT MAIN SHUT OFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR SERVICE. FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. WARNING IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH.
You must maintain the following minimum clearances from combustible and noncombustible construction: I INTRODUCTION Clearances SAFETY PRECAUTIONS WARNING THIS SYMBOL WARNS YOU THAT SERIOUS BURNS OR OTHER INJURIES MAY RESULT IF SAFETY INSTRUCTIONS ARE NOT FOLLOWED. Combustible Noncombustible Construction Construction Back 6” 0” Right Side 6” 0” Left Side 6” 0” You must install this appliance at least 16 inches away from any open flame.
Installed in accordance with all local codes, or in the absence of local codes, with the current National Fuel Gas Code Z223.1/NFPA 54, Natural Gas Installation CAN/CGA-B149.1 or Propane Installation Code CAN/CGA-B149.2 II INSTALLATION This fryer MUST be installed, inspected, calibrated and serviced by qualified and/or certified and/or licensed service personnel – you may void your Keating warranty if installation is not completed per current local, national and Keating specifications.
Counter model and floor model fryers must be restrained to prevent tipping when installed in order to avoid splashing, spilling, etc. of hot liquid. The restraining method may be a manner of installation or by separate means. WARNING IF DISCONNECTION OF THE RESTRAINT IS NECESSARY, IT MUST BE RECONNECTED WHEN THE FRYER IS RETURNED TO ITS ORIGINALLY INSTALLED POSITION. LEVELING The fryer will operate at its highest efficiency when properly leveled. Place a level on fryer vessel from side to side.
A 3/4” NPT manual gas valve is factory installed with each floor model fryer (for single fryers and batteries), except for 10x11AA – 20AA models which use a 1/2” NPT valve. The required gas pressure for proper operation of each fryer is 4” water column for natural gas and 10” water column for Propane gas at the burner manifold. Remove the allen head test plug on the gas manifold and use a manometer to check the gas pressure. 4. Have your plumber or gas company representative light the constant pilot.
Figure 3-2 CAUTION: Oil expands when heated. The “Fill Level” line has been provided to ensure optimum cooking while ensuring the safety of the operator. Do not overfill the fryer vessel. Rear Drain Operating Handle Figure 3-1 Fill Level Line A. AA and CMG Models 1. Open the main gas supply to unit (usually at rear) by turning handle in-line with gas piping or hose. Also open manual valve (red gas cock) on gas piping inside unit where applicable. 2.
7. Set the thermostat to the desired temperature (325°F - 335°F). USE ONLY KEATING APPROVED BASKETS IN YOUR FRYER. NEVER OVERFILL FRY BASKETS. DO NOT BANG BASKETS ON BASKET HANGERS OR FRYER VESSEL. MELTING CARE SHOULD BE TAKEN WHEN LOWERING BASKETS INTO FRYER TO PREVENT SPLASHING HOT OIL FROM FRYER VESSEL. The Keating Melt Cycle safely melts solid shortening in the fryer vessel without scorching. NEVER LIFT BASKETS DIRECTLY OUT OF THE FRYER VESSEL WITHOUT DRAINING AS SEVERE INJURY MAY RESULT.
6. Push “START/STOP” button on timers(s). Basket(s) will automatically lower into fryer vessel. Figure 3-3 Operator in safety gear 7. When cooking cycle is complete, an audible alarm will sound and the basket(s) will raise automatically. Allow oil to drain before removing baskets. D. CPU Model See separate fryer instructions or call 1-800-KEATING. SHUTDOWN A. AA and CMG Models 1. Turn fryer On/Off switch to “OFF” position. Figure 3-4 2.
3. Drain oil from fryer. Filtering may be done at this step. Figure 3-5 Nutroilator filter and fryer 4. Remove oil container to a secure area to prevent accidental spillage. 5. Fill fryer vessel to “Fill Level” line with water. WARNING UNDER NO CIRCUMSTANCES SHOULD THE FRYER BE LEFT UNATTENDED DURING BOIL-OUT. TRAINED PERSONNEL MUST BE PRESENT DURING THE PROCEDURE TO PREVENT BOIL OVER OR TO TURN OFF THE POWER IF WATER DROPS BELOW HEAT TRANSFER TUBES. 6.
Make certain power to the timer has been OFF for at least 30 seconds. Then PRESS and hold down the UP arrow button while turning the rocker power switch to the ON position. WARNING WHEN YOUR FRYER IS BEING USED IN CONJUNCTION WITH A CENTRAL FILTER, DISCONNECT POWER SUPPLY BEFORE RESETTING MOTOR TO PREVENT SERIOUS INJURY WHEN RESET SWITCH IS ENGAGED (SEE FILTER MANUAL). Note: If power switch does not turn off timers, the unit must be unplugged (two people may be needed).
PREVENTIVE MAINTENANCE CHART output contacts will close. During the countdown the colon will flash at a one-second rate. When the countdown has reached "00:00" the relay output contacts will open, the display will flash, and the audible alarm will sound. To cancel the audible alarm, press any button. TIME OPERATOR/OWNER FRAME PAUSE FEATURE To pause a cycle in progress, press any button. The relay output contacts will open, the display will flash, and the countdown will pause.
C. Thermostat Bulb Positioning 3. Apply oil resistant flexible sealant onto compression fitting thread before installing fitting into fryer vessel. BEFORE REPLACING, TEST THERMOSTATS: These operational problems can easily corrected by thermostat bulb positioning. be 4. Position bent portion of bulb against far right heat transfer tube and install compression fitting snugly into fryer vessel. Keating’s patented thermostat application is accurate within 2°F of the dial setting between 250°F – 350°F.
A. Trouble shooting The following diagnosis is only to be used as a guide to qualified service personnel. Keating recommends that you use a qualified service company. Call 1-800-KEATING if you need assistance in locating a qualified service company. PROBLEM Constant pilot won’t light. Runner pilot tube won’t light. Runner pilot won’t stay lit. Delayed ignition. Burners won’t come on. PROBABLE CAUSE a. Gas isn’t turned on. a. Turn manual gas valve on.
PROBLEM Flames come out front of fryer. Fryer has poor recovery or runs cold. Fryer is overheating. Oil in fryer vessel smokes. Oil in fryer vessel boils over. Basket-Lift mechanism won’t operate. PROBABLE CAUSE SOLUTION a. Exhaust problems. a. Install deflector to block down draft. Install or adjust flue restrictors. If problem persists, contact your HVAC representative. b. Radiants have slipped forward. b. Reposition radiants. c. Flue blockage. c. Turn fryer and manual gas valve off.
VI PARTS LISTS ORDERING PARTS Parts may be ordered by part number by calling Keating at 1-800-KEATING or your local service company. You may also order on-line at Keating’s part store, www.keatingofchicago.com Refer to the Keating Instant Recovery® Gas fryer Limited Warranty for complete service and ordering information. The model/serial plate is located on the inside of the front door. The serial and model numbers are necessary when ordering.
GAS FRYER ASSEMBLY AA/CMG CONTROL PANEL BB CONTROL PANEL 15 TS CONTROL PANEL
RUNNER PILOT ASSEMBLY See Page 16 for part numbers.
Figure 6-1 ITEM 1 2 3 4 5 6 7 8 9 10 11 12 13 AA and CMG Control Panel DESCRIPTION THERMOSTAT 14CM & 14AA THERMOSTAT 10X11 18 & UP THERMOSTAT DIAL PLATE THERMOSTAT KNOB RETAINING SCREWS FRY/ON/OFF SWITCH PLATE TOGGLE SWITCH, FRY/ON/OFF HI-LIMIT TEST PLATE HI-LIMIT TEST BUTTON NUT WITH BOOT CONTROL PANEL, HOODED HI-LIMIT CONTROL CONTROL PANEL BACK BUSHING, 7/8” 17 QTY PART NUMBER 1 1 1 1 3 1 1 1 1 1 1 1 1 1 023145 035553 030833 004163 004610 007997 004499 004305 004304 009389 CALL 1-800-KEATING 00434
Figure 6-2 ITEM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 BB Control Panel BB & TS Control Panel DESCRIPTION MODEL QTY THERMOSTAT 14 THERMOSTAT 10X11, 18 & UP THERMOSTAT DIAL PLATE THERMOSTAT KNOB RETAINING SCREWS SET OF (4) LIGHTS 120V, WITH PLATES PILOT ON MOMENTARY SWITCH TOGGLE SWITCH, FRY/OFF/MELT TOGGLE SWITCH, MAIN ON/OFF HI-LIMIT TEST BUTTON TIMER, ELECTRONIC MELT CONTROL NUT WITH BOOT CONTROL PANEL, HOODED FLAME SWITCH CONTROL FLAME SWITCH CONTROL BRACKET HI-LIMIT CONTROL CO
Figure 6-3 14" – 24" Basket-Lift Control Panel ITEM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 DESCRIPTION QTY THERMOSTAT 14TS THERMOSTAT 10X11, 18 & UP THERMOSTAT DIAL PLATE THERMOSTAT KNOB RETAINING SCREWS SET OF (4) LIGHTS 120V, WITH PLATES PILOT ON MOMENTARY SWITCH TOGGLE SWITCH, FRY/OFF/MELT TOGGLE SWITCH, MAIN ON/OFF HI-LIMIT TEST BUTTON TIMER, ELECTRONIC MELT CONTROL NUT WITH BOOT CONTROL PANEL, HOODED FLAME SWITCH CONTROL FLAME SWITCH CONTROL BRACKET HI-LIMIT CONTROL CONTROL PANE
Figure 6-4 ITEM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 14” Basket-Lift Housing and Roller Guide DESCRIPTION QTY MOTOR AND WIRE COVER HOUSING, S/S OR CRS REAR COVER, S/S OR CRS LEFT SIDE CRANK BAR AND CAM (Viewing front of fryer) RIGHT SIDE CRANK BAR AND CAM (Viewing front of fryer) MIRCROSWITCH, MOTOR LIMIT MICROSWITCH, BUZZER LIMIT MOTOR, CCW, LEFT (Viewing front of fryer) MOTOR, CW, RIGHT (Viewing front of fryer) BUZZER ON/OFF SWITCH WITH PLATE BUZZER WIRE HARNESS ASSEMBLY, W/PLUG, 6-PRONG RECE
Figure 6-5 ITEM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 18" - 24" Basket-Lift Housing, Roller Guide and Transformer Box DESCRIPTION QTY HOUSING, S/S OR CRS REAR COVER, S/S OR CRS LINEAR ACTUATOR, 24VDC, WITH LIMIT SWITCHES ROLLER FOR LIFT ROD ROLLER PIN ROLLER PIN LOCK LIFT ROD, FOR SPLIT BASKETS BUSHING, PUSH ROD BUSHING RETAINING RING FUSE HOLDER FUSE, ACTUATOR GROUND FAULT, 3A, SC-3 TRANSFORMER RELAY, BASKET-LIFT RECTIFIER, 24VD, WITH WIRES UPPER ACTUATOR CLEVIS PIN, 1/4”x3/4” LOWER ACTUATOR CLEVIS PIN, 1/
VIII WIRING DIAGRAMS AA & CMG WIRING DIAGRAM NOTE: Separate wiring diagrams have been attached to the fryer and on the inside of this manual and should be saved for troubleshooting and maintenance. The wiring diagrams in this section cover standard fryers which may or may not match the diagrams sent with the fryer. Non-standard fryers such as CPU models do not have wiring diagrams printed in this section.
23 TS WIRING DIAGRAM BB WIRING DIAGRAM
24 18” AND ABOVE TS WITH BASKET-LIFT WIRING DIAGRAM 14 TS WITH BASKET-LIFT WIRING DIAGRAM
100% 80% 60% 40% 20% 10% KEATING OF CHICAGO, INC., 1-800-KEATING WWW.KEATINGOFCHICAGO.COM KEATING REFILE/warranty 3/01 All repair services under this Limited Warranty must be authorized by Keating or performed at Keating. Authorization may be obtained by calling 1-800-KEATING within the Continental United States, Alaska, Hawaii, Puerto Rico and Canada during normal business hours (7:00 a.m. through 6:00 p.m. Central Time, Monday through Friday).
SERVICE INFORMATION If you have a service related question call 1-800-KEATING. Please state the nature of the call; it will ensure speaking with the appropriate person. Have your serial and model number available when ordering parts. KEATING OF CHICAGO, INC. Phone: (708) 544-6500 FAX: (708) 544-6505 Toll Free 1-800-KEATING (In U.S. and Canada) www.keatingofchicago.com *As continuous product improvement occurs, specifications may be changed without notice.