User manual
Installation
23/48
Waterdrainage…
Thewaterdrainagefromthetopsidetotherearsideof
thechargingstationmustbeensured.Therefore,ob
servethefollowing:
● Onlyaverticalinstallationofthechargingstationis
permitted.
● Thechargingstationmustbemountedatanangle
of90°(noinclinationispermitted!).
Mountingthechargingstation…
Turnthehangerboltsintotheanchorsuntilthe
threadstillprotrudesapprox.2cm('x').
Usetheshims[A]tocompensateforanyuneven
nessandtoensureawaterdrainagebehindthede
vice.
Positionandmountthechargingstationusingthe
suppliedwashersandnuts.
[A]…Shim
[B]…Chargingstationhousing
[C]…Washer
[D]…Nut