User manual

Installation
29/48
4.5.3 Enableinput[X1](excludingeseries)
Theenableinputisequippedforusewithapotentialfreecontact.Usingtheenableinput,itispossibleto
controlthechargingstationusingexternalcomponents(e.g.externalkeyswitches,ripplecontrolreceiverof
theenergysupplier,housecontrol,timeswitches,combinationlock,photovoltaicsystemetc.).
Circuitdiagram:
Electricalrequirements:
Outsideofthedevice,asecureisolationtodangerousvoltagesmustbeensuredforthiscontrolline.
Logicalfunction:
Enablecontact Stateofthechargingstation
open BLOCKED
closed READYFOROPERATION
Connection:
Connectthewirestotheenableinput(pleaserefertothe"4.5.5Terminals[X1/X2](excludingeseries)"
chapterfordetailsabouttheterminal).
DIPswitchsetting…
TheuseoftheenableinputmustbeactivatedbyaDIP
switchsetting.
Useenableinput:
"Yes":DSW1.1=ON
"No":DSW1.1=OFF(Default)