OnlyonemaximumvaluecanbesetwiththefollowingDIPswitcheswhichissmallerorequalto
theoperatingcurrentaccordingtothetypeplate:
SETTINGTHEAMPERAGE(DSW1)(*1)
Current DIPSwitch Figure
D1.6 D1.7 D1.8
10A OFF OFF OFF
13A ON OFF OFF
16A OFF ON OFF
20A ON ON OFF
25A OFF OFF ON
32A ON OFF ON
(*1)Presetmaximumchargingcurrentvalueforthevehicle(ControlPilotDutyCycle).
OBTAINIPADDRESSVIADHCP(NOADDRESSING)
DSW2.1toDSW2.4=OFF/DSW2.5=OFF/DSW2.6=OFF
ThechargingprocedureinSTANDARDmodeiscarriedoutautomati
callybythechargingstationwithouthigherrankingcontrolsystem.
ThechargingstationattemptstoobtainanIPaddressviaDHCPserver,
ifneeded.
Thisalsocorrespondstothebasicsettingsforchargingstationswithout
networkconnection.