Installation
36/48
USEFIXEDIPADDRESS
DSW2.1toDSW2.4/DSW2.5=OFF/DSW2.6=ON
Sincemultiplechargingstationsarelocatedinanetwork;anaddressing
ofthechargingstationsisnecessary.
AddressingisdoneusingtheDIPswitchesDSW2.1toDSW2.4.
ThesettableEthernetaddressesstartat10+DIPswitchsetting.
Withthe4bitaddressing,theaddresses11to26canbeused[192.168
.25.xx].
DSW2.1=Addressbit2
0
(value=1)
DSW2.2=Addressbit2
1
(value=2)
DSW2.3=Addressbit2
2
(value=4)
DSW2.4=Addressbit2
3
(value=8)
Exampleforaddress"17":
DSW2.1=ON(Value=1)
DSW2.2=ON(Value=2)
DSW2.3=ON(Value=4)
DSW2.4=OFF(Value=0)
Address=10+1+2+4+0=17
CONNECTIONTOHIGHERRANKINGCOMMUNICATIONMODULE
DSW2.1toDSW2.4=OFF/DSW2.5=ON/DSW2.6=OFF
Activatecommunicationhubmode.
Requiredfortheconnectionwithe.g.the
KeContactC10CommunicationHubfor
OCPPConnection(fordetails,see"KeCon
tactC10CommunicationHubInstallation
Manual".
D2.5 ON=yes
PLCMODEM(DSW2.7)
DeactivatePLCmodem D2.7 ON=yes
COMMISSIONINGMODE(DSW2.8)
Activatingthecommissioningmode
(fordetails,seeChapter"4.7.1Commission
ingmode/selftest").
D2.8 ON=yes
SetD2.1toD2.7toOFF!