User manual

Installation
37/48
4.7 Commissioning
Generalcommissioningprocess
1) Removeallresidualinstallationandconnectionmaterialsfromtheconnectionarea.
2) Beforecommissioning,checkallscrewandterminalconnectionsfortightness!
3) Checkwhetherallunusedcablescrewconnectionsareproperlysealedwithblindplugsordummyscrew
fittings.
4) Ensurethatthevoltageofthepowersupplylineisswitchedon.ThestatusLEDshouldstarttoslowly
flashgreenafter1520seconds.
Thedeviceperformsaselftesteverytimeitisswitchedon.
5) Performthespecifiedinitialtestsaccordingtothelocallyapplicableregulationsandlaws(seeChapter
"4.7.1Commissioningmode/selftest").
6) Closetheconnectorpanelcovertothechargingstation.
7) Mountthehousingcover(seeChapter"4.7.3Mountingthehousingcover").
4.7.1 Commissioningmode/selftest
Thechargingstationcanbeplacedintoacommissioningmodeforsupportingtheinitialsystemtest.During
this,aselftestofthedeviceisperformed(interlocking,contactoractivation,currentmeasurement,etc.)and
theresultisdisplayed.
Aftersuccessfultestwithoutconnectedvehicle,thecontactorisswitchedforlimitedtimeinordertofacilitate
theinitialtests.Anormalchargingprocedureisnotpossibleincommissioningmode.Theinterlockingofthe
connectorsocketisactivatedtopreventacablefrombeingpluggedin.
Aswitchingonofthechargingstationincommissioningmodeviathepowersupplylineleadstoafaultfor
safetyreasons(whiteredredred)inordertopreventanunintendedactivation.
Activatingthecommissioningmode
SettheDIPswitchDSW2.8toON(see"4.6DIPswitchsettings").
Performaresetofthechargingstation.Todothis,pressthe[servicebutton]for1second.
ThecommissioningmodeisnowactivatedandsignalizedbytheorangestatusLED.
Younowhavetheoptionforapproximately5min.tocontactwithstandardtestprobesusingthemeasur
ingdevice(e.g.Astaco®testprobesfromBEHA)andtoperformthenecessarytests(seeChapter"4.7
.2Safetychecks").
After5min.haveelapsed,thecontactorisdeactivatedinthechargingstationisshutdown.
Deactivatingcommissioningmode
SettheDIPswitchDSW2.8toOFFagain.
Performaresetofthechargingstation.Todothis,pressthe[servicebutton]for1secondorswitchthe
powersupplyoff/on.
Thechargingstationstartsupagaininnormalmodeandisreadyforoperation.